Chloride penetration into concrete in an offshore platform-analysis of exposure conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
25
0
3

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2
2

Relationship

2
8

Authors

Journals

citations
Cited by 92 publications
(32 citation statements)
references
References 27 publications
4
25
0
3
Order By: Relevance
“…Porém, em estruturas reais que necessitem passar por trabalhos de inspeção, o método se mostra ineficiente pelo fato de que estas estruturas apresentam certo avanço da frente de carbonatação associada ou não a contaminação por cloretos. Este foi o motivo que o método de aspersão de solução de nitrato de prata não foi usado nos trabalhos de Medeiros et al e Medeiros Junior et al [16,17].…”
Section: Teste Do "Falso Positivo" -Concreto Carbonatado {Sem Cloretos}unclassified
“…Porém, em estruturas reais que necessitem passar por trabalhos de inspeção, o método se mostra ineficiente pelo fato de que estas estruturas apresentam certo avanço da frente de carbonatação associada ou não a contaminação por cloretos. Este foi o motivo que o método de aspersão de solução de nitrato de prata não foi usado nos trabalhos de Medeiros et al e Medeiros Junior et al [16,17].…”
Section: Teste Do "Falso Positivo" -Concreto Carbonatado {Sem Cloretos}unclassified
“…Particularly in coastal areas, many structures such as with bridges, apartment buildings, and public facilities have been demolished before the expected service lives or the repair/maintenance cost has been higher than the initial construction cost. Therefore, many studies have been conducted to extend the service lives of concrete structures by improving the chloride resistance [5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…However, the introduction of reinforcement in concrete may result in degradation problems in reinforced concrete structures due to corrosion that, in advanced states, may lead the structure to ruin. In this sense, studies highlight that the maintenance and rehabilitation of structures degraded by corrosion involve significant financial amounts [1][2][3][4]. The effects of corrosion in reinforced concrete structures involve consequences to the mechanical properties of the bars, mainly due to a decrease of their transversal section and of the adherence between concrete and protruding reinforcing steel [5,6].…”
Section: Introductionmentioning