Background
A Viabahn stent graft (SG) is a heparin-coated self-expandable SG for lower extremity arterial disease that exhibits high flexibility and accuracy in the delivery system. This study aimed to evaluate the short-term efficacy and safety of emergency endovascular treatment (EVT) using a Viabahn SG for upper and lower extremity arterial bleeding (ULEAB).
Methods
Consecutive patients with ULEAB who underwent emergency EVT using the Viabahn SG between January 2017 and August 2021 were retrospectively reviewed. The indications for EVT, location of artery, technical success, clinical success, limb ischemia, periprocedural complications, bleeding-related mortality, 30-day mortality, diameter of the target artery, diameter of the SG, neck length, rebleeding, endoleaks, and patency of the SGs at 1, 3, 6, and 12 months were evaluated.
Results
EVT using the Viabahn SG was performed in 22 patients (mean age, 72.0 ± 13.0 years; 11 men) and 23 arteries (upper, 6; lower, 17). The indications for EVT were pseudoaneurysm (n = 13, 59.1%), extravasation (n = 9, 39.1%), and inadvertent arterial cannulation (n = 1, 4.3%). The anatomical locations of the 23 ULEAB injuries were the brachiocephalic (1 [4.3%]), subclavian (3 [13.0%]), axillary (1 [4.3%]), brachial (1 [4.3%]), common iliac (4 [17.4%]), external iliac (8 [34.8%]), common femoral (2 [8.7%]), superficial femoral (2 [8.7%]), and popliteal (1 [4.3%]) arteries. The technical and clinical success rates were 100%. The rates of limb ischemia, periprocedural complications, and bleeding-related mortality were 0%, whereas the 30-day mortality rate was 22.7%. The mean diameters of the arteries and SGs were 7.7 ± 2.2 and 8.9 ± 2.3 mm, respectively. The mean neck length was 20.4 ± 11.3 mm. No endoleaks or rebleeding occurred during the follow-up period (mean, 169 ± 177 days). Two SG occlusions without limb ischemia occurred in the external iliac and brachial arteries after 1 and 4 months, respectively. Subsequently, cumulative SG patency was confirmed after 1, 3, 6, and 12 months in 91.7%, 91.7%, 81.5%, and 81.5% of patients, respectively.
Conclusions
Emergency EVT using the Viabahn SG for ULEAB was effective and safe according to short-term outcomes. Appropriate size selection and neck length are important for successful treatment. SG patency was good after 1, 3, 6, and 12 months.