2016
DOI: 10.1016/j.ophtha.2016.05.038
|View full text |Cite
|
Sign up to set email alerts
|

Chromatic Multifocal Pupillometer for Objective Perimetry and Diagnosis of Patients with Retinitis Pigmentosa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

2
38
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 26 publications
(40 citation statements)
references
References 43 publications
2
38
0
Order By: Relevance
“…The LMCV parameter was found to be relatively constant throughout the 16.28 visual field in healthy subjects. 18 High variability in LMCV between different VF locations was observed in RP patients, correlating with vision loss, and ROC analysis demonstrated the usefulness of this parameter for RP diagnosis with high specificity and sensitivity. 18 The present study was aimed at characterization of these three pupil response parameters at different light intensities at central and peripheral targets of a 248 VF for in depth characterization of the rod and cone photoreceptor mediated PLR in healthy subjects and as a model for future clinical testing of retinal and optic nerve pathologies.…”
mentioning
confidence: 82%
See 4 more Smart Citations
“…The LMCV parameter was found to be relatively constant throughout the 16.28 visual field in healthy subjects. 18 High variability in LMCV between different VF locations was observed in RP patients, correlating with vision loss, and ROC analysis demonstrated the usefulness of this parameter for RP diagnosis with high specificity and sensitivity. 18 The present study was aimed at characterization of these three pupil response parameters at different light intensities at central and peripheral targets of a 248 VF for in depth characterization of the rod and cone photoreceptor mediated PLR in healthy subjects and as a model for future clinical testing of retinal and optic nerve pathologies.…”
mentioning
confidence: 82%
“…A custom software was used to analyze the PLR parameters (Accutome, Inc., Malvern, PA, USA). 18 Automatically excluded were tests in which the subject blinked during the first 2.5 seconds (when the light stimulus was on and during the contraction phase of the PLR) and tests in which the pupil diameter was increasing during the first 0.45 seconds following light onset. These test points were retested.…”
Section: Pupil Measurement and Analysismentioning
confidence: 99%
See 3 more Smart Citations