2013
DOI: 10.2116/analsci.29.787
|View full text |Cite
|
Sign up to set email alerts
|

Chromatographic Behavior of Selenoproteins in Rat Serum Detected by Inductively Coupled Plasma Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 27 publications
1
11
0
Order By: Relevance
“…The peak detected at the retention time of 11.0 min was assigned to extracellular glutathione peroxidase (GPX3), and the peak at the retention time of 13.5 min was assigned to selenoprotein P (SELENOP) according to our previous literature [12]. The abbreviations of the selenoproteins (GPX3 and SELENOP) were adopted in accordance with the latest nomenclature [13].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The peak detected at the retention time of 11.0 min was assigned to extracellular glutathione peroxidase (GPX3), and the peak at the retention time of 13.5 min was assigned to selenoprotein P (SELENOP) according to our previous literature [12]. The abbreviations of the selenoproteins (GPX3 and SELENOP) were adopted in accordance with the latest nomenclature [13].…”
Section: Resultsmentioning
confidence: 99%
“…Specifically, we evaluated the bioavailability from the recoveries of two serum selenoproteins, GPX3 and SELENOP, in Se-deficient rats by speciation analysis with an LC-ICP-MS. We have already established a speciation analysis for the determination of the two serum selenoproteins [12], which gives us more qualitative data than Western blotting and enzyme activity determination. In particular, the enzyme activity of SELENOP is still unknown.…”
Section: Discussionmentioning
confidence: 99%
“…The chromatographic behaviour of two mayor selenoproteins (extracellular gluthatione peroxidise and selenoprotein P) in serum of four rodent species HPLC (multi gel permeation column, 7.5 id  300 mm) coupled to ICP-MS and ICP-MS-MS have been compared. 183 Although the amino acid sequences in the rodent species is identical, different chromatographic behaviour was noted for selenoproteins derived from rat serum. Two well-separated Se-peaks were detected in rat serum whereas in mouse, hamster and guinea pig serum only one broad Sepeak was detected.…”
Section: Seleniummentioning
confidence: 99%
“…35 This MO + mass shift improved detection limits for phosphorus (P), sulfur (S) and silicon (Si) over those obtained from isotope dilution (ID)-ICP-SF-MS in both aqueous 34 and organic matrices. 34,36 However if O 2 reaction has the potential to produce unwanted polyatomic species; then alternative reaction/collision gases may be used, e.g. NH 3 /He for the ultra-trace detection of titanium (Ti; as Ti(NH 3 ) 6 + ) in biological fluids.…”
Section: Introductionmentioning
confidence: 96%