2003
DOI: 10.1023/b:phac.0000014857.33465.d7
|View full text |Cite
|
Sign up to set email alerts
|

Chromatographic Determination of Stevioside in Raw Plant Material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…S2 shows the improvised process of isolation and purification process of steviosides with recovery yield of sweet glycosides in the range of 85–98%, of which steviosides‐A (85–95%) and rebaudioside‐A (3–8%) and the purity and the chemical structure of the stevioside confirmed through HPLC, LC‐Mass and NMR spectral analysis and compared with literature data. (Kedik et al ., ; Chaturvadula et al ., ; Puri et al ., ) The melting point of the isolated white stevioside powder was 197–199 °C and observed spectral data of the product was 1 H NMR (300 MHz) δ0.98 (s, 3H, C 20 CH 3 ), 1.21 (s, 3HC 18 ‐CH 3 ), 4.86 (S, 1H, C 17 ‐H) 5.21 (S, 1H, C 17 ‐H) 4.59 (D, J = 7.9 Hz, 1H) 5.38 (D, J = 7.9 Hz, 1H); +ESIMS (M + Na) + m/z 827.3891 (calcd. for C38H60O18Na:827.3891).…”
Section: Resultsmentioning
confidence: 99%
“…S2 shows the improvised process of isolation and purification process of steviosides with recovery yield of sweet glycosides in the range of 85–98%, of which steviosides‐A (85–95%) and rebaudioside‐A (3–8%) and the purity and the chemical structure of the stevioside confirmed through HPLC, LC‐Mass and NMR spectral analysis and compared with literature data. (Kedik et al ., ; Chaturvadula et al ., ; Puri et al ., ) The melting point of the isolated white stevioside powder was 197–199 °C and observed spectral data of the product was 1 H NMR (300 MHz) δ0.98 (s, 3H, C 20 CH 3 ), 1.21 (s, 3HC 18 ‐CH 3 ), 4.86 (S, 1H, C 17 ‐H) 5.21 (S, 1H, C 17 ‐H) 4.59 (D, J = 7.9 Hz, 1H) 5.38 (D, J = 7.9 Hz, 1H); +ESIMS (M + Na) + m/z 827.3891 (calcd. for C38H60O18Na:827.3891).…”
Section: Resultsmentioning
confidence: 99%
“…The eluent flow rate velocity was 0.9 mL min −1 . The wavelength of UV detector was 203 nm [26]. The standard reference material for ST was purchased from the National Institute for Food and Drug Control (HPLC≥99%).…”
Section: Methodsmentioning
confidence: 99%
“…The sample aliquots were subjected to analysis as a dry extract evaluation and analysis using high-performance liquid chromatography with a diode-array detector (HPLC/DAD) [32,33]. For the analysis of the dry extract, 10 mL of sample was placed in an oven until a constant weight was obtained.…”
Section: Hplc Analysismentioning
confidence: 99%