2018
DOI: 10.3390/mi9100500
|View full text |Cite
|
Sign up to set email alerts
|

Chronic Intracortical Recording and Electrochemical Stability of Thiol-ene/Acrylate Shape Memory Polymer Electrode Arrays

Abstract: Current intracortical probe technology is limited in clinical implementation due to the short functional lifetime of implanted devices. Devices often fail several months to years post-implantation, likely due to the chronic immune response characterized by glial scarring and neuronal dieback. It has been demonstrated that this neuroinflammatory response is influenced by the mechanical mismatch between stiff devices and the soft brain tissue, spurring interest in the use of softer polymer materials for probe en… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
53
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 51 publications
(56 citation statements)
references
References 50 publications
3
53
0
Order By: Relevance
“…Over the past decade, there has been a renewed interest in the use of thin films and other “soft” electrode materials to create high‐channel, yet low geometric area electrodes with a Young's modulus closer to native tissue to minimize initial surgical trauma and the chronic immune response . These electrode development strategies include the use of PDMS substrates with conductive traces and electrode contacts to develop stretchable multicontact electrode arrays for stimulation and recording .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Over the past decade, there has been a renewed interest in the use of thin films and other “soft” electrode materials to create high‐channel, yet low geometric area electrodes with a Young's modulus closer to native tissue to minimize initial surgical trauma and the chronic immune response . These electrode development strategies include the use of PDMS substrates with conductive traces and electrode contacts to develop stretchable multicontact electrode arrays for stimulation and recording .…”
Section: Resultsmentioning
confidence: 99%
“…These electrode development strategies include the use of PDMS substrates with conductive traces and electrode contacts to develop stretchable multicontact electrode arrays for stimulation and recording . Additionally, shape memory polymer (SMP) or other “shuttles” have been used to create a stiff carrier to facilitate implantation of electrodes into the brain, yet leave a soft electrode chronically to minimize the immune response of tissue . Similarly, the Charles Lieber group has demonstrated that a ultraflexible open mesh electrode array can be injected into the rodent brain via syringe and minimize the chronic immune response, enabling high‐quality chronic recordings for periods of at least 12 weeks .…”
Section: Resultsmentioning
confidence: 99%
“…In previous works, the Voit Lab has presented in vitro and in vivo biocompatibility test results assessing cytotoxicity and neurotoxicity of the substrate SMP material 19,2224 . Cytotoxcity tests using NCTC fibroblasts and primary cortical neurons 24 , and neurotoxicity tests using MEA-based functional assays 19,24 and in vitro glial scarring assays 24 were carried out.…”
Section: Introductionmentioning
confidence: 99%
“…Comparison among different strategies of stimulation of PNS to evoke tactile percepts. Parameters that have been considered are: i) number of subjects (S) and implant duration; ii) type of implanted electrode, number of channels, nerve target; iii) impedance measurement; iv) type of stimulation pattern; v) threshold charge/current over time; vi) …”
Section: Implantable Neuroprostheses In Clinical Applicationsmentioning
confidence: 99%
“…Plexon offers solutions data acquisition and stimulation systems but also electrodes for research needs for cortical recordings (channel counts up to 32 with platinum–iridium contacts) …”
Section: Future Of Neuroprostheticsmentioning
confidence: 99%