1934
DOI: 10.1021/ja01321a510
|View full text |Cite
|
Sign up to set email alerts
|

Chronometric Catalytic Method for the Determination of Micro Quantities of Iodine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
60
0
1

Year Published

1974
1974
2023
2023

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 203 publications
(62 citation statements)
references
References 0 publications
1
60
0
1
Order By: Relevance
“…Iodine concentrations were evaluated by photometric procedure (Photometer ECOM 6122, Eppendorf, Hamburg, Germany) based on Sandell & Kolthoff reaction (19,20) in the modification of Lorenz-Wawschinek et al (21,22). The calibration range of this method has a detection limit of 1-300 mg/l.…”
Section: Clinical Chemical Measurementsmentioning
confidence: 99%
“…Iodine concentrations were evaluated by photometric procedure (Photometer ECOM 6122, Eppendorf, Hamburg, Germany) based on Sandell & Kolthoff reaction (19,20) in the modification of Lorenz-Wawschinek et al (21,22). The calibration range of this method has a detection limit of 1-300 mg/l.…”
Section: Clinical Chemical Measurementsmentioning
confidence: 99%
“…Kinetic spectrophotometric methods, which are based on the reaction, found by Sandell and Kolthoff (1934) set the foundation for the development of different methods for the determination of iodine in environmental samples (mostly water). The said reaction proceeds according to the following equation (1) Iodine has a catalytic effect upon the course of reaction (1), i.e., the more iodine is present in the preparation to be analyzed, the more rapidly proceeds the reaction (1).…”
Section: Water Samplesmentioning
confidence: 99%
“…The lower the determined concentration of cerium (IV) ions, the faster the reaction, thus a larger amount of catalyzing agent, i.e., iodine. By these means it is possible to directly and quantitatively measure the iodine concentration of the test solution, though execution of such processes is complicated and demands extensive measuring times (Sandell & Kolthoff, 1934, 1937. The above-described method was modified in various ways, for example by replacing H 2 SO 4 with HNO 3 (used for acidifying the reaction mixture).…”
Section: Water Samplesmentioning
confidence: 99%
“…On the other hand, kinetic methods of analysis are very simple and low-cost alternatives for iodide determination. Among them, the very sensitive Ce(IV)-As(III) [12][13][14][15][16] and NO2 --[Fe(SCN)] 2+ reactions [17][18][19] have been frequently used. The reaction system Bromopyrogallol Redchloramine T 20 was applied for determination of I -with very poor reproducibility.…”
Section: Introductionmentioning
confidence: 99%