2018 IEEE International Conference on Electrical Systems for Aircraft, Railway, Ship Propulsion and Road Vehicles &Amp; Interna 2018
DOI: 10.1109/esars-itec.2018.8607268
|View full text |Cite
|
Sign up to set email alerts
|

Circulating Current control of a Modular Multilevel Converter (MMC) with State Feedback Controller and Harmonic Current Suppression

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…) are the function of the measured average capacitor voltage. Since the measured capacitor voltages are obtained mostly using LPF or moving average filters (MAF) [34][35][36][37] the virtual capacitor current cvir i could be generated from the measured voltage variation shown in Figure 9, with minimal noise without the use of any additional filter, and given by:…”
Section: Lvir I This Is Possible As Both Currents ( Cvir I and Lvir Imentioning
confidence: 99%
“…) are the function of the measured average capacitor voltage. Since the measured capacitor voltages are obtained mostly using LPF or moving average filters (MAF) [34][35][36][37] the virtual capacitor current cvir i could be generated from the measured voltage variation shown in Figure 9, with minimal noise without the use of any additional filter, and given by:…”
Section: Lvir I This Is Possible As Both Currents ( Cvir I and Lvir Imentioning
confidence: 99%
“…In MMC voltage source inverters, the switching frequency is crucial and restricts how quick the VSI can respond to changes from one operating condition to another, therefore the optimal and achievable inner current control band which is also restricted by the employed switching frequency. That is, the controller bandwidth shows how accurate and fast a control signal could change in time, hence how accurate and fast the MMC system response could be [38]. The MMC based inverter based on the cascade control has the current vector control as the inner current control (ICC), and the outer control that comprises the active and reactive power control.…”
Section: Introductionmentioning
confidence: 99%
“…The PID and hysteresis are the most common [38]. The hysteresis current control is the fastest control in terms of dynamic response however gives more distortions due to the low order harmonics, variable switching frequency and effect of dead time [37][38]. In the other word, PI-current controllers have maintained switching frequency but that at the expense of a slower response.…”
Section: Introductionmentioning