2010
DOI: 10.1007/s00134-010-2051-x
|View full text |Cite
|
Sign up to set email alerts
|

Circulating high sensitivity troponin T in severe sepsis and septic shock: distribution, associated factors, and relation to outcome

Abstract: PurposeTo assess the clinical utility of a recently developed highly sensitive cardiac troponin T (hs-cTnT) assay for providing prognostic information on patients with sepsis.MethodscTnT levels were measured by the novel hs-cTnT assay at two time points (inclusion and 72 h thereafter) in a subgroup of patients from the FINNSEPSIS study and associations with clinical outcomes were examined. Results for the hs-cTnT assay were compared to those of the established fourth-generation cTnT assay.ResultscTnT measured … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

8
114
1
7

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 162 publications
(130 citation statements)
references
References 39 publications
8
114
1
7
Order By: Relevance
“…However, only 3 studies used TnT values 2. By contrast, other investigators have failed to validate troponin as an independent predictor of mortality in addition to severity of illness scores 9, 27, 28, 29…”
Section: Discussionmentioning
confidence: 99%
“…However, only 3 studies used TnT values 2. By contrast, other investigators have failed to validate troponin as an independent predictor of mortality in addition to severity of illness scores 9, 27, 28, 29…”
Section: Discussionmentioning
confidence: 99%
“…1) (13). Four hundred seventy patients were included, and blood samples were available from 232 patients at ICU admission (median, 9 [Q1-Q3, [3][4][5][6][7][8][9][10][11][12][13][14][15][16][17] hr from study inclusion to sampling) and from 201 patients after 72 hours.…”
Section: Methodsmentioning
confidence: 99%
“…We measured NT-proBNP by the Elecsys proBNP assay (Roche Diagnostics, Penzberg, Germany) (4) and chromogranin A (CgA) by a commercially available radioimmunoassay (EuroDiagnostica, Malmö, Sweden) (15). hs-TnT levels were measured by the Elecsys TNT hs STAT assay (Roche Diagnostics) in a subgroup of the patients with severe sepsis (n = 207) as previously reported (5). Cortisol was measured by an immunoassay in the patients who had not received corticosteroids prior to blood sampling, and free cortisol was calculated by the Coolens method (16).…”
Section: Biochemical Analysesmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, it is a useful prognostic predictor independent of left ventricular ejection fraction or B-type natriuretic peptide in patients with congestive HF and non-ischemic dilated cardiomyopathy. In sepsis, measurements of circulating hs-cTnT may be an early marker for shock (Røsjø et al, 2011). These results demonstrate that hs-cTnT is a much more sensitive and timely detector for AMI than cTnT.…”
Section: Discussionmentioning
confidence: 99%