Circumventing glass vial and diluent effects on solution stability of small molecule analytes during analytical method development and validation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…Glass vials are known to contain silanol active sites on their surface, which can interact with certain analytes and lead to declined recoveries. As the FEVE completely removes the sample matrix for maximum recovery of the analytes, sample vial inertness can have substantial impacts on the recoveries. Five different brands of 2 mL sample vials were tested and compared.…”
Section: Resultsmentioning
confidence: 99%
“…Glass vials are known to contain silanol active sites on their surface, which can interact with certain analytes and lead to declined recoveries. As the FEVE completely removes the sample matrix for maximum recovery of the analytes, sample vial inertness can have substantial impacts on the recoveries. Five different brands of 2 mL sample vials were tested and compared.…”
Section: Resultsmentioning
confidence: 99%
“…The remaining barrier to this goal was the large and inconsistent variation in pH observed as a pH-adjusted stock solution of DBA was dispensed across an array of mildly alkaline borosilicate glass vials, an impact observed in other studies. 36 In order to achieve tight and reproducible control of pH, polypropylene vials were used for our studies. Full details of the automated experimental protocol can be found in the Experimental Section.…”
Section: ■ Methodologymentioning
confidence: 99%
“…Our aim was to implement a small-scale automation platform for our nitrosation experimental protocol, with the consequent advantages of being able to study many alternative sets of conditions, with parallel replicates, in a high-throughput workflow. The remaining barrier to this goal was the large and inconsistent variation in pH observed as a pH-adjusted stock solution of DBA was dispensed across an array of mildly alkaline borosilicate glass vials, an impact observed in other studies . In order to achieve tight and reproducible control of pH, polypropylene vials were used for our studies.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation