2022
DOI: 10.1016/j.jpba.2022.114958
|View full text |Cite
|
Sign up to set email alerts
|

Cis-Δ9-tetrahydrocannabinolic acid occurrence in Cannabis sativa L.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 23 publications
0
16
0
Order By: Relevance
“…The method was applied to analyze all phytocannabinoids and HHC epimers in ethanolic extracts of two hemp biomass samples (HHC-1 and HHC-2), one HHC hashish sample (HHC-3), and a pure HHC sample (HHC-4) (Figure S5, Supporting Information). Extraction of the analytes was performed using ethanol, as previous studies have demonstrated its superior ability to extract this class of compounds 2 4 , 24 – 26 . The chromatograms of the extracts were examined for interfering compounds using HRMS, which confirmed the absence of other cannabinoids at the retention time of the analytes.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The method was applied to analyze all phytocannabinoids and HHC epimers in ethanolic extracts of two hemp biomass samples (HHC-1 and HHC-2), one HHC hashish sample (HHC-3), and a pure HHC sample (HHC-4) (Figure S5, Supporting Information). Extraction of the analytes was performed using ethanol, as previous studies have demonstrated its superior ability to extract this class of compounds 2 4 , 24 – 26 . The chromatograms of the extracts were examined for interfering compounds using HRMS, which confirmed the absence of other cannabinoids at the retention time of the analytes.…”
Section: Resultsmentioning
confidence: 99%
“…The HESI parameters were optimized in previous works for cannabinoids: spray voltage 4200 kV and 3800 kV for HESI + and HESI- mode respectively, sheath gas 70 au, auxiliary gas 5 au, sweep gas 0.5 au, ion transfer tube temperature 390 °C and vaporizer temperature 150°C 26 , 29 . The mass analyzer was operated in both full scan (FS) and data-dependent acquisition (DDA) mode.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Area of the peaks for each analyte was plotted against nominal concentration and the back-calculated concentration was checked to be within 15% of the nominal value. Samples of hemp in orescence and HHC hashish were extracted using the method reported in the German Pharmacopoeia for the extraction of phytocannabinoids from cannabis in orescence 21 . The extracts HHC-1 and HHC-2 from hemp in orescence were analysed after 100× dilution with mobile phase, while the extract HHC-3 from HHC hashish was 1000× diluted.…”
Section: Methodsmentioning
confidence: 99%
“…This is for a few potential reasons: (1) the compounds often do not have the possibility of forming chiral centers; this is typically because there are chemical bonds that are not saturated, i.e., the compound contains double bonds; (2) the compounds only have atomic centers with duplicate substituents, for instance, two hydrogens or two carbons; (3) the plant preferentially only synthesizes one of the enantiomers as a requirement for downstream processes. Because most of the compounds of interest (namely cannabidiol (CBD) and tetrahydrocannabinol (THC)) exist naturally as only a single isomer (with some low levels of other isomers having been reported recently [ 13 , 14 , 15 ]), the literature contains hundreds of examples of separations on classical achiral phases such as silica or octadecyl silane (ODS or C 18 ) [ 16 , 17 , 18 , 19 , 20 ].…”
Section: Introductionmentioning
confidence: 99%