An Applied Guide to Water and Effluent Treatment Plant Design 2018
DOI: 10.1016/b978-0-12-811309-7.00028-x
|View full text |Cite
|
Sign up to set email alerts
|

Classic mistakes in water and effluent treatment plant design and operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0
2

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 0 publications
0
5
0
2
Order By: Relevance
“…The high TDS value in the downstream or station 4 because of domestic, agricultural, fishery, and industrial waste flows from upstream to downstream. The TDS values measured at the four sampling locations are still in the category of natural waters, which are usually less than 500 mg/L (Moran, 2018). In addition, TDS value in Cihampelas River was still below the class 2 river water quality standard of 1000 mg/L in GR No.…”
Section: Methodsmentioning
confidence: 81%
“…The high TDS value in the downstream or station 4 because of domestic, agricultural, fishery, and industrial waste flows from upstream to downstream. The TDS values measured at the four sampling locations are still in the category of natural waters, which are usually less than 500 mg/L (Moran, 2018). In addition, TDS value in Cihampelas River was still below the class 2 river water quality standard of 1000 mg/L in GR No.…”
Section: Methodsmentioning
confidence: 81%
“…Total dissolved solids (TDS) measure the water samples’ organic matter and inorganic salts [ 58 ]. Moran (2018) mentioned that TDS above 500 mg/L is not suitable to use as drinking water [ 58 ].…”
Section: Resultsmentioning
confidence: 99%
“…Total dissolved solids (TDS) measure the water samples’ organic matter and inorganic salts [ 58 ]. Moran (2018) mentioned that TDS above 500 mg/L is not suitable to use as drinking water [ 58 ]. Based on the findings, TDS from before treatment (705.67 ± 12.60 mg/L) and after 5 days of treatment was reduced in all treatments, including control (582.67 ± 5.55 mg/L), thus indicating that bacterial-based bioremediation was developed into nonsterile synthetic wastewater.…”
Section: Resultsmentioning
confidence: 99%
“…selanjutnya proses kembali di Water Treatment Plan terlebih dahulu agar air tersebut dapat di gunakan sebagai air produksi di PT.X. Terkait hal tersebut suatu pembangkit listrik PT.X harus menerapkan prinsip pengendalian limbah secara cermat dan terpadu baikSistem Pengolahan Air Limbah (Waste Water Treatment Plant) oleh sebab itu karakteristiknya perlu dipelajari secara seksama [13] Umumnya dalam proses pengolahan air di WWTP (wast water treatment plant) untuk menjernihkan air menggunakan koagulan yang berfungsi sebagai penjernih, salah satu penjernih air yang rendah korosi serta perawatan yang mudah, harganya yang murah dan cepatnya reaksi penjernihan. jenis koagulan tersebut yakni koagulan PAC (poly aluminium cloride) di kenal dengan perawatan yang mudah dan harganya yang cukup murah sehingga air yang menggunakan koagulan PAC akan menghasilkan air yang lebih jernih, dan air tersebut memenuhi spesifikasi yang sesuai ditentukkan.…”
unclassified
“…Tunggu sekitar 10 menit sampai pH meter menujukkan hasil yang stabil dan tetap 6. Catat hasil pH air pada form data[13] Bilas Beaker glass dengan sampel air 2. Bilas Conductivity meter dengan sampel air yang akan dianalaisis 3.…”
unclassified