1998
DOI: 10.1006/abio.1998.2714
|View full text |Cite
|
Sign up to set email alerts
|

Cleanup and Analysis of Sugar Phosphates in Biological Extracts by Using Solid-Phase Extraction and Anion-Exchange Chromatography with Pulsed Amperometric Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
66
0

Year Published

1999
1999
2010
2010

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 73 publications
(67 citation statements)
references
References 32 publications
1
66
0
Order By: Relevance
“…Measurement of Intracellular Metabolites-The cell extracts from aerobic batch cultivations and cleanup of sugar phosphates (Gal-1-P, Glu-1-P, Glu-6-P, Man-6-P, and Fru-6-P), were obtained by applying a method described previously (24). Cell extracts were obtained using cold methanol as quenching agent and chloroform as extraction solvent.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Measurement of Intracellular Metabolites-The cell extracts from aerobic batch cultivations and cleanup of sugar phosphates (Gal-1-P, Glu-1-P, Glu-6-P, Man-6-P, and Fru-6-P), were obtained by applying a method described previously (24). Cell extracts were obtained using cold methanol as quenching agent and chloroform as extraction solvent.…”
Section: Methodsmentioning
confidence: 99%
“…Cell extracts were obtained using cold methanol as quenching agent and chloroform as extraction solvent. Furthermore, cleanup of sugar phosphates was done using solid-phase extraction (24). Determination of sugar phosphates was done by anionexchange chromatography with pulsed amperometric detection as described previously (24).…”
Section: Methodsmentioning
confidence: 99%
“…Sugars, sugar phosphates, sugar alcohols and peptides were determined simultaneously by GC-MS after methoxymation and silylation derivatization, following the protocol described by Roessner et al (2000). The determination of extracellular sugar phosphates for the evaluation of leakage during quenching was performed using solid-phase extraction and high-pressure ion-exchange chromatography with pulsed amperometric detection (HPIC-PAD), according to Smits et al (1998).…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…Two different inlet inserts were used, depending on the derivatives to be analysed: Siltek gooseneck splitless deactivated liner (Restek, USA), 4.0 mm i.d., was used for analysis of MCF derivatives, and split straight liner with glasswool (Agilent Technologies, USA) for the TMS-derivatives. HPIC-PAD analysis was performed with a Dionex BioLC (Dionex, Sunnyvale, CA, USA) and the analytes were separated in a CarboPac PA1 column (Dionex) and a Dionex PA1 guard column at 30 • C, under conditions described by Smits et al (1998).…”
Section: Analytical Proceduresmentioning
confidence: 99%
See 1 more Smart Citation