2010
DOI: 10.1007/s00586-010-1447-1
|View full text |Cite
|
Sign up to set email alerts
|

Clinical application of C2 laminar screw technique

Abstract: C2 laminar screws have become an increasingly used alternative method to C2 pedicle screw fixation. However, the outcome of this technique has not been thoroughly investigated. A total of 35 cases with upper cervical spinal instability undergoing C2 laminar screw fixation were reviewed. All cases had symptoms of atlantoaxial instability, such as craniocervical junction pain, and were fixed with the Vertex cervical internal fixation system. A total of 68 screws were placed and hybrid constructs (a C2 translamin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0
2

Year Published

2011
2011
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 28 publications
(25 citation statements)
references
References 14 publications
0
23
0
2
Order By: Relevance
“…The data from general population may not apply to patients with OO. In addition, the use of C2 laminar screws in atlantoaxial fixation in attempt to reduce the risk for the vertebral artery (VA), was first reported by Wright et al [36] in 2004 and since became popular [18,19,38]. For OO patients, however, a couple of questions arise: can C2 pedicle screw be safely placed in every OO patient?…”
Section: Introductionmentioning
confidence: 99%
“…The data from general population may not apply to patients with OO. In addition, the use of C2 laminar screws in atlantoaxial fixation in attempt to reduce the risk for the vertebral artery (VA), was first reported by Wright et al [36] in 2004 and since became popular [18,19,38]. For OO patients, however, a couple of questions arise: can C2 pedicle screw be safely placed in every OO patient?…”
Section: Introductionmentioning
confidence: 99%
“…Ma et. al [13] lately reported on their results using C2 laminar screws for atlantoaxial instability. They had no insertion-related intraoperative complications, and all screws were placed properly.…”
Section: Discussionmentioning
confidence: 97%
“…Губин и др. Задняя фиксация краниоцервикального перехода с использованием винтовых конструкций ции вероятность развития псевдоартроза может достигать 30 % [18,23,25,29]. В настоящее время наиболее надежной является задняя фиксация с использованием полиаксиальных винтов и стержней.…”
Section: хирургия позвоночникаunclassified