2016
DOI: 10.1016/j.adro.2016.03.005
|View full text |Cite
|
Sign up to set email alerts
|

Clinical application of lying-on-the-floor total skin electron irradiation for frail patients with cutaneous lymphoma: An emphasis on the importance of in vivo dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 7 publications
(18 reference statements)
0
7
0
Order By: Relevance
“…Two courses were delivered using a lying-on-the floor position due to poor performance status and inability to remain standing throughout the length of treatment. 9,11 Most patients had significant debility and were unable to tolerate eye shields because of an unacceptable risk of falling. Accordingly, eye shields were not routinely used.…”
Section: Methodsmentioning
confidence: 99%
“…Two courses were delivered using a lying-on-the floor position due to poor performance status and inability to remain standing throughout the length of treatment. 9,11 Most patients had significant debility and were unable to tolerate eye shields because of an unacceptable risk of falling. Accordingly, eye shields were not routinely used.…”
Section: Methodsmentioning
confidence: 99%
“…In vivo dosimetry was performed to verify that adequate dose was delivered to the inframammary fold using methods previously described. 3 , 4 Briefly, a 2 × 2 cm 2 piece of Gafchromic EBT3 film (Ashland ISP Advanced Materials, Bridgewater, NJ), each wrapped in a single layer of plastic wrap, was taped onto each patient's skin in the inframammary fold after the patient was fitted with the sling. The plastic wrap served to keep the films clean for scanning and analysis, and was discarded after treatment and before analysis.…”
Section: Methodsmentioning
confidence: 99%
“…Film analysis was performed using FILMQA Pro Software (Ashland ISP Advanced Materials), using the methodology described in prior work. 3 , 4 The average dose was taken from a 1 cm × 1 cm region of interest that was centered on each film. Only 1 set of measurements was obtained from each patient.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…While there are many excellent papers [6,20,[28][29][30][31][32][33][34] and an AAPM Task Group Report [35] which provide a vast amount of valuable information relevant to film dosimetry, the process outlined here is meant to be a concise summary of the necessary basic fundamentals that are required for accurate RCF dosimetry. The methods described have been used in our clinic for more than six years, both in routine clinical tasks such as in vivo TSE measurements [36,37] and IMRT QA [14] as well as in research in conventional x-ray [16,21,38] and proton therapy [39] studies. While certainly not the only approach for successful film dosimetry, they should help potential RCF users to implement RCF into clinical practice within a relatively quick timeframe.…”
Section: Introductionmentioning
confidence: 99%