Clinical Correlates and Reference Intervals for Pulmonary Artery Systolic Pressure Among Echocardiographically Normal Subjects

Abstract: Background-Data in normal human subjects on the factors affecting pulmonary artery systolic pressure (PASP) are limited. We determined the correlates of and established a reference range for PASP as determined by Doppler transthoracic echocardiography (TTE) from a clinical echocardiographic database of 102 818 patients, of whom 15 596 (15%) had a normal Doppler TTE study. Methods and Results-A normal TTE was based on normal cardiac structure and function during complete Doppler TTE studies. The PASP was calcul… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

16
382
8
14

Year Published

2004
2004
2012
2012

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 599 publications
(420 citation statements)
references
References 24 publications
16
382
8
14
Order By: Relevance
“…The present authors assumed the right atrial pressure to be 5 mmHg, since all subjects had normal vena cava diameters and respiratory variability. The current upper limit of normal values (PASP 41 mmHg) agrees well with a study establishing normal values in a large number of subjects when one considers that these investigators assumed the right atrial pressure to be 10 mmHg [20]. Furthermore, the current measurements are in agreement with other studies assessing PASP at rest and during exercise [20][21][22][23][24].…”
Section: Pulmonary Vascular Responsesupporting
confidence: 87%
“…The present authors assumed the right atrial pressure to be 5 mmHg, since all subjects had normal vena cava diameters and respiratory variability. The current upper limit of normal values (PASP 41 mmHg) agrees well with a study establishing normal values in a large number of subjects when one considers that these investigators assumed the right atrial pressure to be 10 mmHg [20]. Furthermore, the current measurements are in agreement with other studies assessing PASP at rest and during exercise [20][21][22][23][24].…”
Section: Pulmonary Vascular Responsesupporting
confidence: 87%
“…Age was expected to influence Ppa, since catheterisation data at rest in two groups of healthy individuals (17 aged [48]. In the present patient series, associations of Ppa measurements with age were performed using Spearman rank analyses and linear regression.…”
Section: Statisticsmentioning
confidence: 99%
“…At birth, pressure within the pulmonary artery falls (mean pressure ~15 mm Hg), and it receives all of the right ventricular output after closure of the ductus arteriosus (20). This change from high pressure/low flow to low pressure/high flow, when it occurs prematurely, may result in abnormal changes to the walls of the pulmonary artery.…”
mentioning
confidence: 99%