2007
DOI: 10.4158/ep.13.7.721
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Efficacy and Patient Satisfaction with U-500 Insulin Pump Therapy in Patients with Type 2 Diabetes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
41
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(41 citation statements)
references
References 19 publications
0
41
0
Order By: Relevance
“…Administration of U-500 insulin via multiple daily injections showed an increase or no significant change in weight. Conversely, one study using continuous infusion administration revealed a 24.3% decrease in weight [22]. Overall, both methods of administration of U-500 insulin are effective.…”
Section: Choice Of Methods Of U-500 Insulin Deliverymentioning
confidence: 81%
See 2 more Smart Citations
“…Administration of U-500 insulin via multiple daily injections showed an increase or no significant change in weight. Conversely, one study using continuous infusion administration revealed a 24.3% decrease in weight [22]. Overall, both methods of administration of U-500 insulin are effective.…”
Section: Choice Of Methods Of U-500 Insulin Deliverymentioning
confidence: 81%
“…Each study showed a statistically significant decrease in HbA 1c with an average of 2.02% across the studies. Three of the four studies demonstrated no significant change in total daily insulin dose, whereas the other study reported a decrease in total daily insulin doses [22]. The effect of U-500 insulin given via infusion on weight is unclear at this time with [22], no change [23], and weight gain all reported [9, 24••].…”
Section: U-500 Use By Continuous Subcutaneous Insulin Infusionmentioning
confidence: 96%
See 1 more Smart Citation
“…U-500 dose rates and ratios may be converted either by dividing or multiplying by 5 for continuous subcutaneous insulin infusion (CSII). [13][14][15] U-500 in insulin pumps has been evaluated in small retrospective studies and one prospective study, as well as a few case reports. [13][14][15][16] …”
Section: Concentrated Insulin For Insulin Pumpmentioning
confidence: 99%
“…Humulin U-500R dose rates and ratios may be converted by either dividing or multiplying by 5 for CSII. [44][45][46] Newer products may not be available in vials to avoid the dose conversion necessity. BIOD-531, which demonstrates similar activity with the exception of faster onset of action compared with Humulin U-500R, is also a potential insulin which may be useful in pumps.…”
Section: Concentrated Insulin For Insulin Pumpsmentioning
confidence: 99%