1984
DOI: 10.1016/0022-3913(84)90371-8
|View full text |Cite
|
Sign up to set email alerts
|

Clinical evaluation of cast metal resin-bonded anterior fixed partial dentures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

1985
1985
2010
2010

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(9 citation statements)
references
References 8 publications
0
9
0
Order By: Relevance
“…There were 11 studies with less than 2 years of postplacement evaluation 73,77,78,[81][82][83]85,87,89,97,105 and a mean debonding rate of 10%. Twenty-six studies [74][75][76]79,80,86,[90][91][92][93][94]96,[98][99][100][101]108,109,[111][112][113][114][115][116]119,120 ranged in length from 2 to 5 years with a mean debonding rate of 20%. A mean debonding rate of 24% was associated with the 11 studies 84,88,95,[102][103][104]106,107,110,117,118 evaluating prostheses for periods in excess of 5 years.…”
Section: Debondingmentioning
confidence: 99%
See 3 more Smart Citations
“…There were 11 studies with less than 2 years of postplacement evaluation 73,77,78,[81][82][83]85,87,89,97,105 and a mean debonding rate of 10%. Twenty-six studies [74][75][76]79,80,86,[90][91][92][93][94]96,[98][99][100][101]108,109,[111][112][113][114][115][116]119,120 ranged in length from 2 to 5 years with a mean debonding rate of 20%. A mean debonding rate of 24% was associated with the 11 studies 84,88,95,[102][103][104]106,107,110,117,118 evaluating prostheses for periods in excess of 5 years.…”
Section: Debondingmentioning
confidence: 99%
“…This complication, the second most common, was reported in 7 studies. [79][80][81]103,105,106,108 Five of the studies 80,81,103,105,108 provided a percentage incidence, whereas 2 others 79,106 reported its occurrence but did not indicate the number of prostheses affected by this complication. The 5 studies, when combined, indicate that 62 of 343 prostheses exhibited tooth discoloration for a mean incidence of 18% and a range of 3% to 37%.…”
Section: Abutment Tooth Discolorationmentioning
confidence: 99%
See 2 more Smart Citations
“…[31][32] The most common type of failure with resin-bonded FPDs is debonding of the cast metal framework from the luting cement; however, debonding of the luting cement from the enamel surface has also been reported. [33][34] Teeth have some degree of mobility under function, which causes repeated tensile and compressive stresses at the interface between the metal framework and the composite luting cement. Repeated stress can predispose fatigue failures of the adhesive joint.…”
mentioning
confidence: 99%