Purpose: Descemet membrane endothelial keratoplasty (DMEK) is currently regarded as the most effective surgical procedure for addressing Fuchs Endothelial Corneal Dystrophy (FECD), frequently performed in conjunction with cataract surgery. In this retrospective study, we present a comparison of visual performance, clinical outcomes, and optical quality between two types of monofocal Intraocular Lenses (IOLs): one standard and one enhanced intermediate vision model, implanted in patients who underwent combined phacoemulsification and DMEK surgery. Methods: This single center comparative retrospective study was conducted at the Eye Clinic of the University of Florence (Italy) and included a total of 48 eyes of 48 patients affected by FECD and cataract. All patients underwent combined DMEK with phacoemulsification procedures. The patients’ data were analyzed and divided into two groups: one group (standard group) consisted of 24 eyes that underwent phaco-DMEK with implantation of a monofocal IOL, and the second group (enhanced monofocal group) included 24 eyes that underwent phaco-DMEK with implantation of an enhanced monofocal IOL. In both groups, the following monocular visual outcomes were evaluated 6 months after surgery: Uncorrected Distance Visual Acuity (UDVA) and Best-Corrected Distance Visual Acuity (BCDVA) at 4 mts; Uncorrected Intermediate Visual Acuity (UIVA), Distance-Corrected Intermediate Visual Acuity (DCIVA) at 66 cm; Uncorrected Near Visual Acuity (UNVA) and Best Corrected Near Visual Acuity (BCNVA). Monocular defocus curves were also assessed. Furthermore, optical quality in terms of Contrast Sensitivity (CS) in photopic conditions, Higher-Order Aberrations (HOAs) at a pupil size of 5 mm. Modulation Transfer Function (MTF), Objective Scatter Index (OSI), and Strehl ratio, were also analyzed. A Patient-Reported Spectacle Independence Questionnaire was revised to evaluate spectacle independence outcomes. Results: the two groups did not exhibit statistically significant differences in terms of UDVA, BCDVA, UNVA and BCNVA, photopic CS, HOAs, OSI, Strehl ratio, and MTF. However, in the phaco-DMEK enhanced monofocal IOL group, significantly better results were observed in terms of UIVA and DCIVA as well as a different defocus curve profile at 1.50 D, providing better defocus results at intermediate distance compared with the ZCB00 IOL. Conclusion: In our study, we found that enhanced monofocal lens performed favorable visual outcomes, even in cases of FECD, compared to standard monofocal IOLs. Comparable optical quality observed in the Eyhance group could allow surgeons to consider these lenses as a viable option for selected patients with FECD.