2002
DOI: 10.1016/s0003-4975(02)03796-7
|View full text |Cite
|
Sign up to set email alerts
|

Clinical performance and biocompatibility of poly(2-methoxyethylacrylate)—coated extracorporeal circuits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

3
41
0
3

Year Published

2005
2005
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 54 publications
(47 citation statements)
references
References 7 publications
3
41
0
3
Order By: Relevance
“…Also, in our previous studies, we have demonstrated data clarifying the platelet preservation effects of polymer coating. 29 In this study, we aimed at using dual-effect to overcome AF occurrence; filtration of activated leukocytes and blood management. Post-operative bleeding was less in the study group and inflammatory markers demonstrated better clinical outcome.…”
Section: Discussionmentioning
confidence: 99%
“…Also, in our previous studies, we have demonstrated data clarifying the platelet preservation effects of polymer coating. 29 In this study, we aimed at using dual-effect to overcome AF occurrence; filtration of activated leukocytes and blood management. Post-operative bleeding was less in the study group and inflammatory markers demonstrated better clinical outcome.…”
Section: Discussionmentioning
confidence: 99%
“…Reduced circuits with less priming volume and the lack of venous reservoir are associated to decreased cytokine release, neutrophil and platelet activation 42 . Poly-coated circuits (2-methoxyethylacrylate) have been related to lower inflammatory reaction 43 . It is still necessary to establish direct causal links between postoperative or post-CPB inflammatory response, physiological pulmonary changes during MR with CPB and patients' clinical evolution.…”
Section: Discussionmentioning
confidence: 99%
“…A utilização de circuitos reduzidos com menor volume de primming, a ausência de reservatório venoso está associada à redução da liberação de citocinas, da ativação neutrofílica e plaquetária 42 . Circuitos recobertos com Poly (2-methoxyethylacrylato) foram relacionados com menor reação inflamatória 43 . Ainda é necessário o estabelecimento de ligações causais diretas entre a resposta inflamatória após cirurgia ou CEC, alterações na fisiologia pulmonar durante a cirurgia de RM com CEC e a evolução clínica dos pacientes.…”
unclassified
“…There were more leukocytes adhered on noncoated (60 cells/dL) than on the coated (14 cells/dL) oxygenator fibers. It appears that with less protein adsorption, [16][17][18] fewer leukocytes adhered to the coated fibers.…”
Section: Stm Studiesmentioning
confidence: 99%
“…In previous studies, we found that more platelets adhered to the noncoated fiber surfaces. [16][17][18] The adsorbed immunoglobulin and adhered leukocytes on foreign surfaces triggered complement activation via the alternative pathway. Complement activation on PMEA-coated surfaces was less due to less IgG adsorption and leukocyte adhesion.…”
Section: Stm Studiesmentioning
confidence: 99%