2007
DOI: 10.1016/j.jhsa.2007.02.005
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Results of Absorbable Plates for Displaced Metacarpal Fractures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
41
1

Year Published

2009
2009
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(43 citation statements)
references
References 24 publications
(22 reference statements)
1
41
1
Order By: Relevance
“…In that study, no foreign-body reactions were observed after a 6-month followup [10]. However, that interval was considerably shorter than that observed in our study for the occurrence of foreign-body reactions.…”
Section: Discussioncontrasting
confidence: 69%
“…In that study, no foreign-body reactions were observed after a 6-month followup [10]. However, that interval was considerably shorter than that observed in our study for the occurrence of foreign-body reactions.…”
Section: Discussioncontrasting
confidence: 69%
“…[1][2][3][4]10,24,25] In vitro biomechanical comparative studies have shown that dorsal plating is the most stable fixation method. [2,10,33,34] K wire fixation may be made percutaneously in a cross, transverse, or intramedullary manner. K wires are easily available in the operating rooms, and are easily applied.…”
Section: Discussionmentioning
confidence: 99%
“…These potential benefits have been supported by reports demonstrating favourable results in treating fractures with these resorbable systems 4,[10][11][12][13][14][15] . However, conventional resorbable materials are associated with inflammatory reaction, can generate sterile sinus formation, result in incomplete remodelling of the bone and exhibit improper dynamics between device strength retention and wound healing 11,12,16 .…”
mentioning
confidence: 82%
“…However, conventional resorbable materials are associated with inflammatory reaction, can generate sterile sinus formation, result in incomplete remodelling of the bone and exhibit improper dynamics between device strength retention and wound healing 11,12,16 . They are primarily limited to specific applications such as paediatric craniofacial reconstruction 10 , fixation of metacarpal fractures [13][14][15] and long-term soft-tissue moudling 17 due to their lower strength and stiffness. In addition, the fragility of conventional resorbable plates and screws requires careful pretapping of the screw hole and insertion while the plates need to be pre-shaped to the exact curvature of the fracture location 14 .…”
mentioning
confidence: 99%
See 1 more Smart Citation