2013
DOI: 10.1016/j.jdent.2013.10.009
|View full text |Cite
|
Sign up to set email alerts
|

Clinical risk factors related to failures with zirconia-based restorations: An up to 9-year retrospective study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
74
1
6

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 118 publications
(84 citation statements)
references
References 34 publications
3
74
1
6
Order By: Relevance
“…Chipping of the veneering ceramic and loss of retention were technical complications also reported for multiple-unit zirconia based FDPs [15][16][17], occurring significantly more often at the zirconia-based FDPs than at metal-ceramics [18]. The more recent clinical studies showed that despite all developments and efforts for the improvement of the veneering procedures of zirconia frameworks, the problem of chipping of the zirconia veneering ceramic has not been eliminated yet [19,20]. Consequently, zirconia-based single crowns should not be considered as the primary treatment option for now, and patients need to be thoroughly informed about current limitations.…”
Section: Discussionmentioning
confidence: 99%
“…Chipping of the veneering ceramic and loss of retention were technical complications also reported for multiple-unit zirconia based FDPs [15][16][17], occurring significantly more often at the zirconia-based FDPs than at metal-ceramics [18]. The more recent clinical studies showed that despite all developments and efforts for the improvement of the veneering procedures of zirconia frameworks, the problem of chipping of the zirconia veneering ceramic has not been eliminated yet [19,20]. Consequently, zirconia-based single crowns should not be considered as the primary treatment option for now, and patients need to be thoroughly informed about current limitations.…”
Section: Discussionmentioning
confidence: 99%
“…Results of this study agreed with the findings of several clinical studies. It was numerously reported that chipping was the most frequently encountered clinical failure, although interfacial failures between zirconia cores and ceramic veneers were still encountered [2][3][4][27][28][29] . In the present study, the authors did not investigate the effects of aging by thermocycling on bond strength, which would make the experimental condition more analogous to the oral environment.…”
Section: Discussionmentioning
confidence: 99%
“…Leucite, for example, displays an unsatisfactory failure which is revealed in a high incidence of fracture or chipping [3,8,12,14,15,25,28,[30][31][32][33]. The strong increase of chipping with time, as discussed in reference [33] for glass-ceramic veneers on ZrO 2 substrate indicates that many parameter and fatigue mechanisms contribute to eventual failure.…”
Section: Selected Mechanical Propertiesmentioning
confidence: 99%