“…In their article initially describing the clinical implications of the AG, Emmett and Narins defi ned the AG and detailed its utility in evaluating a patient's acid-base status (2). Th e serum AG is calculated from the laboratory measurement of electrolytes and provides important information regarding a patient's acidbase status.…”
“…In their article initially describing the clinical implications of the AG, Emmett and Narins defi ned the AG and detailed its utility in evaluating a patient's acid-base status (2). Th e serum AG is calculated from the laboratory measurement of electrolytes and provides important information regarding a patient's acidbase status.…”
“…Standard nomogram is used to correct the base excess for hemoglobin [9,10]. A multicompartmental model developed by Wooten is used to correct the Figge-Fencl equations for haemoglobin [21].…”
Section: Discussionmentioning
confidence: 99%
“…Standard base excess is a calculated from P a CO 2 and pH. When the base excess is positive it is termed as alkalosis, while when the base excess is negative or there is base deficit, it is termed as acidosis [1,[8][9][10]. Anion gap is defined as the difference between the anions and the cations in the blood.…”
Section: Standard Base Deficit/excess (Copenhagen) Approachmentioning
confidence: 99%
“…SID e = (HCO 3 -) + (charge on albumin) + (charge on phosphate) [10] Weak acids charge depends on pH, and so can be calculated as The sum of the weak acids (albumin and phosphate) is called as A TOT as they exists in both dissociated form (A -) as well as nondissociated form (AH).…”
Section: Strong Ions Difference and Gap (Stewart-fencl Approach)mentioning
“…Because the total concentration of anions and cations in plasma is equal, the AG reflects the difference between the concentration of unmeasured anions and cations. 1 A normal AG primarily reflects the concentration of nonbicarbonate buffers including albumin, phosphate, sulfate, and organic acids. Albumin is the main component of the normal AG with each gram per deciliter contributing 2.5 mEq/L to the gap calculation.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.