2001
DOI: 10.1016/s0049-3848(00)00431-x
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Utility of the Platelet Function Analyzer (PFA-100) for the Assessment of the Platelet Status in Patients with Congestive Heart Failure (EPCOT trial)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2003
2003
2008
2008

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 22 publications
0
8
0
Order By: Relevance
“…Despite the fact the several studies have sought to use the CT in a prospective manner to diagnose platelet function abnormalities that could lead to thrombosis in humans, test results are highly variable and therefore limited in their ability to consistently correlate with severity of disease or to predict future cardiac events 28–30 . We were unable to identify shorter CTs in cats with HCM.…”
Section: Resultsmentioning
confidence: 93%
“…Despite the fact the several studies have sought to use the CT in a prospective manner to diagnose platelet function abnormalities that could lead to thrombosis in humans, test results are highly variable and therefore limited in their ability to consistently correlate with severity of disease or to predict future cardiac events 28–30 . We were unable to identify shorter CTs in cats with HCM.…”
Section: Resultsmentioning
confidence: 93%
“…In this study the platelet function was evaluated using optical aggregometry, flow cytometry and PFA-100 method (aspirin nonresponsiveness was identified when 4 of the following 5 parameters occurred: collagen-induced aggregation > 70%; adenosine diphosphate-induced aggregation > 60%; whole blood aggregation > 18 ohms; expression of active GP IIb-IIIa > 220 log mean flurorescence intensity units; and P-Selectin positivity > 8%). However there is substantial interindividual variability of platelets characteristics in patients with heart failure and PFA-100 method is not a particularly useful device for screening patients with congestive heart failure and monitoring the aspirin use [72].…”
Section: Aspirin Resistance and Heart Failurementioning
confidence: 99%
“…Several studies have been performed with the PFA-100, and have shown that effect of aspirin treatment on platelet function can be measured with this system [16,17]. In previous reports, aspirin non-responsiveness has been described as having a normal closure time by PFA-100 assay despite confirmed treatment with aspirin.…”
Section: Pfa-100 Assaymentioning
confidence: 99%
“…The platelet function analyzer (PFA)-100 (DadeBehring) is a simple, quantitative, whole-blood automatic platelet function assay, which simulates platelet based hemostasis in vitro [14,15]. It is suggested that the PFA-100 may be used to screen the aspirin responder or nonresponder status of patients taking aspirin [16,17]. Aspirin non-responsiveness has been described as having a normal closure time (CT) by PFA-100 assay despite confirmed treatment with aspirin [6,9,11].…”
Section: Introductionmentioning
confidence: 99%