2019
DOI: 10.1103/physrevaccelbeams.22.072804
|View full text |Cite
|
Sign up to set email alerts
|

Closed orbit correction at synchrotrons for symmetric and near-symmetric lattices

Abstract: This contribution compiles the benefits of lattice symmetry in the context of closed orbit correction. A symmetric arrangement of BPMs and correctors results in structured orbit response matrices of Circulant or block Circulant type. These forms of matrices provide favorable properties in terms of computational complexity, information compression and interpretation of mathematical vector spaces of BPMs and correctors. For broken symmetries, a nearest-Circulant approximation is introduced and the practical adva… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…The resulting quadrupole settings variation during a typical dipole magnets ramp (10 T/s) of SIS18 is shown in Fig. 4 into a continuous ORM variation with time [14] as evident from the variation of the highest singular values of the ORMs during the ramp plotted for both planes in Fig. 4 (bottom), although the design (set) tune remains the same.…”
Section: Simulationsmentioning
confidence: 99%
See 2 more Smart Citations
“…The resulting quadrupole settings variation during a typical dipole magnets ramp (10 T/s) of SIS18 is shown in Fig. 4 into a continuous ORM variation with time [14] as evident from the variation of the highest singular values of the ORMs during the ramp plotted for both planes in Fig. 4 (bottom), although the design (set) tune remains the same.…”
Section: Simulationsmentioning
confidence: 99%
“…System interconnection for the application of small gain theorem. a theoretical comparison between SGT and spectral radius condition discussed in inequality 11 based upon following assumptions: 1) we consider circulant or block-circulant ORMs (a scenario which exists for FAIR synchrotrons and also some synchrotron light sources [14]) for which the spectral radius is equal to the H ∞ norm i.e. the highest singular value σ.…”
Section: B Comparison To Small Gain Theoremmentioning
confidence: 99%
See 1 more Smart Citation
“…There may be different reasons that feedback systems have not generally exploited these existing symmetries (one exception is [14]). Firstly, the matrices involved in the feedback systems have around 100,000 elements and recognizing these symmetries by by inspection is not straightforward.…”
Section: Introductionmentioning
confidence: 99%
“…The contributions of the work presented in this chapter can be summarized below, while some of them are also published in [79].…”
Section: Summary and Contributionsmentioning
confidence: 99%