Purpose
This study was to investigate the feasibility and treatment effect of using modified Kirschner wire (K-wire) percutaneous rotation prying reduction combined with Elastic Stable Intramedullary Nailing (ESIN) in children with Judet IV radial neck fracture.
Methods
A retrospective analysis was conducted on 47 children with Judet IV radial neck fracture who underwent treatment with modified K-wire percutaneous rotation prying reduction combined with ESIN from April 2019 to November 2022, including 25 males and 22 females, with an average age of 8.79 years old (ranging from 5 to 14). The study recorded the surgical time, fluoroscopy time, reduction time, and reduction quality evaluated according to the Metaizeau radiological standard. During the last follow-up, the flexion-extension and forearm rotation function of the affected and healthy sides were recorded, and the Mayo Elbow Performance index was used to evaluate the elbow joint function.
Results
The average duration of the operation was 25.51 min (ranging from 14 to 43 min), with a mode of 2 reset times (ranging from 1 to 5) and 8 fluoroscopic times (ranging from 4 to 15). Based on the Metaizeau radiological standard for assessing reduction quality, 45 cases were deemed excellent, while 2 cases were considered good. Following 3–4 weeks of postoperative long-arm cast immobilization, exercises were performed to promote elbow joint and forearm rotation. The ESIN was removed after satisfactory fracture healing around 4 months postoperatively. The average follow-up period was 26.79 months (ranging from 5 to 48). At the final follow-up, the range of motion for the affected limb in flexion, extension, pronation, and supination was (140.23 ± 4.80)°, (4.43 ± 3.98)°, (84.09 ± 4.97)°, and (83.83 ± 4.55)°, respectively. There was no statistically significant difference compared to the healthy side, which had a range of motion of (141.36 ± 3.27)°, (5.28 ± 2.25)°, (85.66 ± 3.20)°, and (84.98 ± 2.57)° (P > 0.05). According to the Mayo Elbow Performance index, 44 cases were rated as excellent and 1 case was considered good.
Conclusion
The modified K-wire percutaneous rotation prying reduction combined with ESIN is an effective treatment for severe radial neck fractures in children. This technique offers several advantages, including the ability to easily “capture” significantly displaced radial heads, achieve rapid and accurate reduction, and reduce radiation exposure.