2022
DOI: 10.1016/j.avsg.2021.10.039
|View full text |Cite
|
Sign up to set email alerts
|

CO2 Automated Angiography in Endovascular Aortic Repair Preserves Renal Function to a Greater Extent Compared with Iodinated Contrast Medium. Analysis of Technical and Anatomical Details

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 19 publications
0
6
0
Order By: Relevance
“…In step 3, the visualization of the contralateral hypogastric artery was 93% with a median good image quality. In our previous experiences, 11,12 the contralateral hypogastric artery was visualized in all cases without any In step 4, the completion CO 2 angiogram provided better images when the injection was performed from the femoral introducer sheath. Again, this result could be misread, because the CO 2 from the introducer was injected after the pigtail injection; the gas still present in the aorta could possibly improve image quality.…”
Section: Discussionmentioning
confidence: 84%
See 3 more Smart Citations
“…In step 3, the visualization of the contralateral hypogastric artery was 93% with a median good image quality. In our previous experiences, 11,12 the contralateral hypogastric artery was visualized in all cases without any In step 4, the completion CO 2 angiogram provided better images when the injection was performed from the femoral introducer sheath. Again, this result could be misread, because the CO 2 from the introducer was injected after the pigtail injection; the gas still present in the aorta could possibly improve image quality.…”
Section: Discussionmentioning
confidence: 84%
“…Beside these technical findings, the most relevant result of our study is that CO 2 -EVAR procedures can be completed with a very minimal amount of iodine injection (median, 17 cc [IQR, 51 cc]), similarly to the case series of Fujihara et al 9 and significantly lower compared with our previous experience. 12 The postoperative outcome in terms of mortality (0%) and renal function (0 mg/dL [IQR, 0.08 mg/dL] of median creatinine increase and 0 mL/min [IQR, 6.5 mL/min] of median eGFR decrease) was excellent. As reported before by Fujihara et al 9 it is important to underline that many type II endoleaks visualized during the procedure tend to spontaneously thrombose before the pre-discharge imaging.…”
Section: Discussionmentioning
confidence: 96%
See 2 more Smart Citations
“…Many of the clinical innovations were born in laboratories and operating rooms. An accurate bench-based evaluation of what happens in biomechanical terms for optimizing procedures has rarely been carried out in-depth, and some aspects can be improved [4][5][6].…”
Section: Introductionmentioning
confidence: 99%