2018
DOI: 10.37358/rc.18.11.6715
|View full text |Cite
|
Sign up to set email alerts
|

Coated copper Wire Calcium Selective Microelectrode for Applications in Dental Medicine

Abstract: A coated wire calcium selective microelectrode for biological use was developed, comprising a PVC selective matrix containing calcium ionophore IV coated on copper wire, previously covered with a solid-state contact mixture. The obtained calcium microsensor presented a Nernstian answer in a concentration range of 10-1 to 10-6 mol/L. The selectivity coefficients over the main interfering ions of biological interest proved that the calcium microelectrode is highly selective. Also, the response time (6s) and repe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2
1

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…The used electrochemical system consisted of a carbon paste solid-contact electrochemical calcium microsensor and a homemade solid-state Ag/AgCl as a micro-reference electrode [7]. The determinations were performed with the help of a multichannel MEDISEN type IEMS-4 potentiometric system, provided by Medisen Medikal Teknolojiler Araştırma Geliştirme San.…”
Section: Methodsmentioning
confidence: 99%
“…The used electrochemical system consisted of a carbon paste solid-contact electrochemical calcium microsensor and a homemade solid-state Ag/AgCl as a micro-reference electrode [7]. The determinations were performed with the help of a multichannel MEDISEN type IEMS-4 potentiometric system, provided by Medisen Medikal Teknolojiler Araştırma Geliştirme San.…”
Section: Methodsmentioning
confidence: 99%
“…To compare the newly developed REs with commercial ones, we prepared and used four different ionselective electrodes (Li + , NH 4 + , Ca 2+ , and NO 3 − ISEs) in the same manner as our previous works. [29][30][31]…”
Section: Preparation Of Solid-state Reference Electrodesmentioning
confidence: 99%
“…As in our previous work, 26 we prepared solid-contact paste after dissolving 50% graphite oxide, 35% epoxy, and 15% hardener in a few drops of THF. Then, the paste was filled into polypropylene tubes (2.5 mm inner diameter, 3.5 mm outer diameter, 50.0 mm length) and attached to a copper wire from one end for establishing a signal connection.…”
Section: Preparation Of Membrane Cocktails and Isesmentioning
confidence: 99%