The type of solvent and the volume used to load pheromone components onto rubber septa had significant effects on pheromone release ratios, the variability of those release ratios, and the recoverability of the volatile components during subsequent extraction with hexane. Volatile release ratios of synthetic Oriental fruit moth (OFM) pheromone and additional volatile compounds were determined using a gas chromatograph column as a volatile trap for rapid (≤1 hr) analysis from individual rubber septa. Volatile compound solutions were prepared in hexane, pentane, CH2Cl2, and methyl tert-butyl ether, and a 10, 33, or 100 μl aliquot of each solution was applied to rubber septa. Septa loaded with 100 μl of CH2Cl2 emitted significantly (P < 0.05) higher alcohol: acetate (OH:Ac) ratios than septa loaded with the other solvents, which were all similar. Release ratios of the alcohol and acetate components of the OFM pheromone components were assessed over a 3 week period using septa loaded with each solvent. Regardless of loading solvent, the OFM OH:Ac ratios declined logarithmically over 3 weeks; however, the decay slope from septa loaded with CH2Cl2 solutions was different from those of the other three solvents, which were nearly all the same. A high variability in OH:Ac release ratios was measured overall, regardless of the solvent used or the volume it was applied in. Four compounds of near-equal mass: 1-dodecanol, 1-dodecanal, methyl decanoate, and tridecane emitted different release ratios dependent on the solvent, hexane or CH2Cl2, with which a septum was loaded. The more polar and the greater the mass of the test compound, the slower it was emitted from a septum regardless of solvent. These combined results plus comparisons to earlier reports, suggest that researchers should empirically assess the release ratios from septa to be used in bioassays rather than just reporting the type of septum, ratios of compounds applied and solvent used to prepare them.