2019
DOI: 10.1107/s1600577519013079
|View full text |Cite
|
Sign up to set email alerts
|

Coherence properties of the high-energy fourth-generation X-ray synchrotron sources

Abstract: Coherence properties of the fourth-generation high-energy storage rings with low-emittance values are discussed.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(21 citation statements)
references
References 32 publications
1
20
0
Order By: Relevance
“…This allows simulating more complex X-ray beamlines like various X-ray microscope or soft X-ray beamlines and compare said simulations with real measurements. Another refinement would be to replace the Gaussian elementary mode with the true singleelectron radiation mode (Khubbutdinov et al, 2019), which would readily lead to an accurate partially coherent source model. We expect further applications of these interesting simulation tools.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…This allows simulating more complex X-ray beamlines like various X-ray microscope or soft X-ray beamlines and compare said simulations with real measurements. Another refinement would be to replace the Gaussian elementary mode with the true singleelectron radiation mode (Khubbutdinov et al, 2019), which would readily lead to an accurate partially coherent source model. We expect further applications of these interesting simulation tools.…”
Section: Discussionmentioning
confidence: 99%
“…For sources that are not diffraction limited it is often a good approximation to model SR sources by assuming that the associated CSD is separable in the Cartesian coordinates (Khubbutdinov et al, 2019),…”
Section: The Genuine Field Representationmentioning
confidence: 99%
See 1 more Smart Citation
“…0. A research papers direct calculation of the normalized degree of coherence from the eigenvalues was also derived by Khubbutdinov et al (2019) and is given by…”
Section: Partially Coherent Ptychographymentioning
confidence: 99%
“…Therefore, it is necessary to increase the size of the flat phase distribution area at the focal plane to meet the experimental requirements. Several software packages have been developed for the simulation of partially coherent beams through beamlines, including SRW (Chubar, 2014;Chubar et al, 2011), HYBRID (Shi et al, 2014), SHADOW3 (Sanchez del Rio et al, 2011), PHASE (Bahrdt et al, 2011) and XRT (Sanchez del Rio et al, 2014;Khubbutdinov et al, 2019). Many works have been carried out using these simulation packages for the beamline design.…”
Section: Introductionmentioning
confidence: 99%