2002
DOI: 10.2214/ajr.178.5.1781087
|View full text |Cite
|
Sign up to set email alerts
|

Coil Sensitivity Encoding in MR Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
2

Year Published

2004
2004
2016
2016

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(5 citation statements)
references
References 4 publications
0
3
0
2
Order By: Relevance
“…Nevertheless, up to 60% of small malignant nodules, particularly those less than 1 cm size in the background of cirrhotic liver, are missed at MRI [19]. Continued improvement in the MR sequences and hardware [20, 21], as well as the advent of liver-specific contrast agents [22, 23], which are only available for MRI, have led to the improved diagnostic performance of MRI. The broad arsenal of MR sequences and multiphasic postcontrast imaging provide comprehensive information on the liver lesion by elucidating different signal intensities that reflect the inherent properties of the lesion's composition, as well as blood flow dynamics, which gives each lesion type different MR characteristic appearances.…”
Section: The Evolution In Magnetic Resonance Imaging (Mri) Of the mentioning
confidence: 99%
“…Nevertheless, up to 60% of small malignant nodules, particularly those less than 1 cm size in the background of cirrhotic liver, are missed at MRI [19]. Continued improvement in the MR sequences and hardware [20, 21], as well as the advent of liver-specific contrast agents [22, 23], which are only available for MRI, have led to the improved diagnostic performance of MRI. The broad arsenal of MR sequences and multiphasic postcontrast imaging provide comprehensive information on the liver lesion by elucidating different signal intensities that reflect the inherent properties of the lesion's composition, as well as blood flow dynamics, which gives each lesion type different MR characteristic appearances.…”
Section: The Evolution In Magnetic Resonance Imaging (Mri) Of the mentioning
confidence: 99%
“…The SNR in the SENSE-implemented sequence depends on acceleration and geometric factors. The latter vary over the image and describe local noise enhancements on the final reconstructed image; the background noise at parallel imaging thus varies with the spatial position (Pruessmann et al 1999 ; Kurihara et al 2002 ). Therefore we did not perform SNR calculations in a traditional way because of their unambiguous definition is difficult.…”
Section: Methodsmentioning
confidence: 99%
“…Paralel inceleme yöntemi ile K alanındaki faz kodlama basamak sayısı azaltılarak inceleme zamanında belirgin derecede azalma sağlanır. 5,10 Faz kodlama basamak sayısının azalması SEN-SE redüksiyon faktörü (R) tarafından sağlanır. Örneğin R=2 seçildiğinde K aralığında mevcut olan faz kodlama basamaklarının yarısı kodlanır.…”
Section: Bulgularunclassified
“…Faz tarayıcı koillerde izlenen, koiller arası intensite farklılıkları SENSE tekniğinin kullanımı ile homojen hale getirilmekte ve görüntü kalitesi belirgin artırılmaktadır. 5 Bu çalışmada malign veya benign karaciğer lezyonu olduğu bilinen veya düşünülen hastalarda çok hızlı T2A (SENSE T2A), TSE T2A ve dinamik kontrastlı T1A MRG yöntemleri kullanılarak, lezyon saptama ve karakterize etmedeki duyarlılıklarının karşılaştırılması amaçlanmaktadır. 6 aylık takip sonrası hemanjiom tanısı kondu.…”
Section: Introductionunclassified