2021
DOI: 10.1177/1687814021994976
|View full text |Cite
|
Sign up to set email alerts
|

Collaborative improvement of efficiency and noise of bionic vane centrifugal pump based on multi-objective optimization

Abstract: The hydraulic and acoustic performance of centrifugal pump is closely related to hydraulic structure parameters, and they are contradictory. In order to solve this contradiction, this paper introduces the pit bionic structure, and proposes an optimization method based on multi-objective test design and response surface to improve the hydraulic and acoustic performance. Taking the bionic vane pit diameter, axial spacing and radial spacing as design variables. Taking the maximum hydraulic efficiency and total so… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 15 publications
2
7
0
Order By: Relevance
“…The calculated values of the two sound sources within 1500 Hz are lower than the measured values. At the blade passing frequency and its octave, the calculated values of the noise are close to the measured values, which is consistent with the law obtained by Liu et al 18…”
Section: Numerical Computationsupporting
confidence: 91%
See 1 more Smart Citation
“…The calculated values of the two sound sources within 1500 Hz are lower than the measured values. At the blade passing frequency and its octave, the calculated values of the noise are close to the measured values, which is consistent with the law obtained by Liu et al 18…”
Section: Numerical Computationsupporting
confidence: 91%
“…The calculated values of the two sound sources within 1500 Hz are lower than the measured values. At the blade passing frequency and its octave, the calculated values of the noise are close to the measured values, which is consistent with the law obtained by Liu et al 18 The relative error increases with the increase in frequency. The primary reason for this phenomenon is that the influence of pipe resonance, motor operation, cavitation, and backflow inside the pump has not been considered in calculating field noise inside the centrifugal pump.…”
Section: Computational Model Validationsupporting
confidence: 90%
“…2.8 | Sound-structure coupling equation [23][24][25] As a widely used acoustic software, Actran software can quickly solve acoustic problems such as radiation, scattering and sealing of sound waves, propagation in pipes, convection effect, acoustic-vibration coupling and so on. Meanwhile, Actran software has excellent robustness, accuracy and operational efficiency.…”
Section: Turbulence Kinetic Energymentioning
confidence: 99%
“…At present, in the research involving multi-objective optimization of centrifugal pump using response surface method, several issues still need to be addressed. Firstly, there is no error between the quantitative response surface model and real value [30,31] . Additionally, there is a lack of comparative validation regarding the calculation accuracy of different turbulence models [32] .…”
Section: Introductionmentioning