2002
DOI: 10.1016/s0360-5442(02)00010-5
|View full text |Cite
|
Sign up to set email alerts
|

Collector efficiency of double-flow solar air heaters with fins attached

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
43
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 121 publications
(45 citation statements)
references
References 14 publications
2
43
0
Order By: Relevance
“…These results were in agreement with the study of Yeh et al (2002) who outlines a considerable performance increase when employing a double-flow device instead of using a singleflow. It could be seen that, performance of single duct front pass collector (SDFP) was significant different compared to double duct parallel flow and double duct counter flow.…”
Section: Comparisons Of Means For Single and Double Pass Solar Collectorsupporting
confidence: 92%
See 2 more Smart Citations
“…These results were in agreement with the study of Yeh et al (2002) who outlines a considerable performance increase when employing a double-flow device instead of using a singleflow. It could be seen that, performance of single duct front pass collector (SDFP) was significant different compared to double duct parallel flow and double duct counter flow.…”
Section: Comparisons Of Means For Single and Double Pass Solar Collectorsupporting
confidence: 92%
“…Suggestions for this settings includes: air passing over absorber plate (single duct front pass-SDFP), air enter over absorber plate and exit below it (double duct counter flow-DDCF) and air passing in both sides of absorber plate (double duct parallel flow). Yeh et al (2002) reported that a considerable improvement in collector efficiency is obtained by employing a double-flow device instead of using a singleflow. The study of Omojaro and Aldabbagh (2010) suggests passing the air from above and below the absorber plate at the same time in a double-flow solar air heater.…”
Section: Influence Of Air Flow Patternsmentioning
confidence: 99%
See 1 more Smart Citation
“…It was observed that introducing obstacles in the air stream increases the absorber plate surface area [13]. Fins are employed in the SAH to extend the surface area of the absorber [14]. The results of attaching pin fins to the absorber plate of SAH indicate that the efficiency improves by 48% compared to SAH without fins [15].…”
Section: Introductionmentioning
confidence: 99%
“…The performance range of flat plate solar collectors indicated by Yeh et al (2002) to a mass flow 38.52 kg/h, is 0.6 to 0.65 (Figure 11). According to Maiiti et al (2011), the yield increases with time in a dryer to a maximum of 60% in a heater plate.…”
Section: The Performance Of Collectormentioning
confidence: 99%