1990
DOI: 10.1111/j.1095-8649.1990.tb03563.x
|View full text |Cite
|
Sign up to set email alerts
|

Colorimetric and refractometer estimates of total plasma protein in striped bass, Morone saxatilis (Walbaum)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
0
0
3

Year Published

1992
1992
2011
2011

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 8 publications
3
0
0
3
Order By: Relevance
“…Several studies showed that the protein scale on a clinical serum refractometer, while correlated to protein concentration, sometimes overestimates the values returned by colorimetric assays of protein in fish serum [26,[30][31][32]. In Crustacea, our work confirms the data previously obtained from other authors suggesting the use of refractometry in order to measure total protein because of the ease, rapid mode of operation, and feasiblity in the field and laboratory [22,23,25].…”
Section: Discussionsupporting
confidence: 84%
“…Several studies showed that the protein scale on a clinical serum refractometer, while correlated to protein concentration, sometimes overestimates the values returned by colorimetric assays of protein in fish serum [26,[30][31][32]. In Crustacea, our work confirms the data previously obtained from other authors suggesting the use of refractometry in order to measure total protein because of the ease, rapid mode of operation, and feasiblity in the field and laboratory [22,23,25].…”
Section: Discussionsupporting
confidence: 84%
“…The average hematocrit (Table 1) fell within most of the hematocrit ranges reported for striped bass in the literature (Engel and Davis 1964;Sherk et al 1972;Tisa and Strange 1983). Values for total plasma protein (Table 1) were comparable to other published refractometer values for the species (Courtois 1976;Westin 1978;Hunn and Greer 1990). However, total protein values obtained with the refractometer averaged about 4 g/dL higher than previous colorimetric measurements (Hunn and Greer 1990).…”
Section: Blood Characteristicssupporting
confidence: 81%
“…Values for total plasma protein (Table 1) were comparable to other published refractometer values for the species (Courtois 1976;Westin 1978;Hunn and Greer 1990). However, total protein values obtained with the refractometer averaged about 4 g/dL higher than previous colorimetric measurements (Hunn and Greer 1990). Because of these discrepancies, we recommend that a colorimetric (chemical) method of analysis be used to better estimate the true level of protein in striped bass plasma or serum.…”
Section: Blood Characteristicssupporting
confidence: 77%
“…Apesar de ser rápido, utilizar reagentes de baixo custo e não apresentar grande variação da absortividade específica para diferentes proteínas 9,20,21,30 , este método não é muito sensível, como foi destacado por diversos autores 20,24,30 , colocando-o em grande desvantagem, em relação a outras metodologias, e por isto tem sido, ao longo dos anos, substituído por métodos mais sensíveis. Mesmo assim, o método de biureto continua sendo recomendado para a determinação da concentração de proteínas totais em plasma sangüíneo pela Associação Americana de Análises Clínicas e por diversos autores 15,16,34 , bem como para a determinação de proteínas totais em saliva 30 e leite 29 , quando comparado com outros métodos.…”
Section: Aplicaçõesunclassified
“…A principal vantagem do método de Lowry é a sua alta sensibilidade e, por isto, tem sido utilizado para a determinação da concentração de proteínas totais em diversos meios, sendo eles: líqüor 20,38 , plasma sangüíneo 34,39,40 , saliva humana 30 10 para determinar proteínas totais em líqüor 38 , tecido animal 41 e tecido vegetal 45 . Os autores 38,41,45 , de maneira geral, recomendam o método de Lowry, pois no estudo comparativo de metodologias o mesmo mostrou-se mais sensível, com melhor exatidão, menor consumo de amostra e, dependendo do caso, menos suscetível a alguns tipos de interferentes.…”
Section: Aplicaçõesunclassified