2020
DOI: 10.1002/slct.202001041
|View full text |Cite
|
Sign up to set email alerts
|

Colorimetric Detection of Copper(II) Ions Using Schiff‐Base Derivatives

Abstract: Two new Schiff base derivatives N,N-dimethyl-4-((2-(phenylthio) phenyl)imino)propenyl)aniline (CSP) and 2-(4-(dimethylamino) phenyl) allylidene) amino)benzenethiol (CSH) were synthesized. Sensing mechanism of the sensors was investigated using UV-Vis spectroscopy in the presence of various metal ions. The sensor CSP shows high sensitivity and selectivity to Cu 2 + over a wide range of other metal ions in acetonitrile (ACN)/water (H 2 O) (v/v 2 : 1). The sensor CSP can detect Cu 2 + ions by color change from ye… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(16 citation statements)
references
References 37 publications
(58 reference statements)
0
16
0
Order By: Relevance
“…L* was highly decreased upon raising the total content of the copper ions to indicate the formation of darker color. a* was increased and switched from negative to positive values [32][33][34] Many colorimetric chemosensors have been developed for detection of copper ions, such as Schiff-Bases, [35] pyrenes, [36] chromones, [37] and metal-organic frameworks. [38] However, these chemosensors have shown disadvantages, such as sophisticated and expensive preparation procedures, poor selectivity, lower limit of detection, and difficult to operate under ambient conditions.…”
Section: Colorimetric Study On Paper Dipstickmentioning
confidence: 99%
“…L* was highly decreased upon raising the total content of the copper ions to indicate the formation of darker color. a* was increased and switched from negative to positive values [32][33][34] Many colorimetric chemosensors have been developed for detection of copper ions, such as Schiff-Bases, [35] pyrenes, [36] chromones, [37] and metal-organic frameworks. [38] However, these chemosensors have shown disadvantages, such as sophisticated and expensive preparation procedures, poor selectivity, lower limit of detection, and difficult to operate under ambient conditions.…”
Section: Colorimetric Study On Paper Dipstickmentioning
confidence: 99%
“… 28 , 34 87 Some designs that have been explored include chemosensors based on rhodamine 44 , 53 , 56 , 57 , 60 , 78 and Schiff-base units. 28 , 37 , 45 , 48 , 51 , 54 , 61 , 62 , 70 , 71 , 76 , 77 It is evident that while there have been many copper sensor designs, sensitivity and selectivity for naked-eye detection remain elusive. For example, of the 55 sensors mentioned above, only 14 sensors displayed naked-eye detection below 10 μM.…”
Section: Introductionmentioning
confidence: 99%
“…For example, of the 55 sensors mentioned above, only 14 sensors displayed naked-eye detection below 10 μM. 34 , 42 , 44 , 50 , 53 , 57 , 61 , 65 , 66 , 69 , 70 , 72 , 76 , 87 Furthermore, only three of the studies challenged copper sensing in the presence of a competing metal ion 34 , 61 , 70 and none challenged copper sensing in the presence of 10-fold excess competing metal to copper, which is achieved in this work.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, some interesting Schiff base derivatives have been synthesized. Specifically, cinnamaldehyde-based Schiff base derivatives have been reported for the monitoring of metal ions such as Cu 2+ (Aydin and Keles, 2020a), Cd 2+ (Aydin and Keles, 2020b), Ag + (Kang et al, 2018), Ni 2+ (Peralta-Dominguez et al, 2015), Al 3+ (Kar et al, 2015: Aydin andKeles, 2017) Cu 2+ /Hg 2+ (Cho et al, 2019).…”
Section: Introductionmentioning
confidence: 99%