2011
DOI: 10.1007/s11434-011-4505-0
|View full text |Cite
|
Sign up to set email alerts
|

Colorimetric detection of glucose and an assay for acetylcholinesterase with amine-terminated polydiacetylene vesicles

Abstract: The colorimetric response of amine-terminated polydiacetylene (PDA) vesicles was initially demonstrated by varying the pH of the solution. Convenient colorimetric methods to detect glucose and acetylcholinesterase (AChE) activity were successfully established using amine-terminated PDA vesicles by taking advantage of the following features: (1) the amine-terminated PDA vesicles undergo a colorimetric transition as the pH of the solution changes; (2) glucose can be oxidized to gluconic acid in the presence of g… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 47 publications
0
10
0
1
Order By: Relevance
“…Some of these approaches include Reverse iontophoresis, electrochemical methods, Sonophoresis, Electromagnetic techniques, and metabolic heat conformation. [21][22][23][24][25][26][27][28][29][30]…”
Section: Interstitial Fluidmentioning
confidence: 99%
See 1 more Smart Citation
“…Some of these approaches include Reverse iontophoresis, electrochemical methods, Sonophoresis, Electromagnetic techniques, and metabolic heat conformation. [21][22][23][24][25][26][27][28][29][30]…”
Section: Interstitial Fluidmentioning
confidence: 99%
“…In enzymatic analysis, the color reaction is preceded by a reaction catalyzed by an enzyme. 30 Finger, arm, eye and skin (sweat, tears, urine) 4,8,53…”
Section: Bio-impedance Spectroscopymentioning
confidence: 99%
“…在 另 一 项 研 究 中 , 张 德 清 等 [49] Yoon等 [53] 则采用另一种底物Myr, 设计了一种检测 与上例使用的材料不同, 张德清等 [54] 使用两端被 氨基取代的PDAs作为载体最后改造成为一种脂质体,…”
Section: 彩图)unclassified
“…All of these features form a unique combination that enhances the colorimetric signal of PDA, enabling the detection of low concentrations of VOCs. In addition, monitoring color changes with graphene‐immobilized PDA membranes can be more easily accomplished than those PDA systems where they are embedded in a polymer matrix17 or in conventional PDA vesicles 28. Kim and co‐workers have also developed multifunctional polydiacetylene/graphene nanohybrids for biosensor applications using the self‐assembly of PDA on reduced graphene oxide 29.…”
Section: Introductionmentioning
confidence: 99%