2010
DOI: 10.1109/jmems.2010.2048095
|View full text |Cite
|
Sign up to set email alerts
|

Comb-Actuated Resonant Torsional Microscanner With Mechanical Amplification

Abstract: A comb-actuated torsional microscanner is developed for high-resolution laser-scanning display systems. Typical torsional comb-drive scanners have fingers placed around the perimeter of the scanning mirror. In contrast, the structure in this paper uses cascaded frames, where the comb fingers are placed on an outer drive frame, and the motion is transferred to the inner mirror frame with a mechanical gain. The structure works only in resonant mode without requiring any offset in the comb fingers, keeping the si… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
45
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
3
1

Relationship

2
7

Authors

Journals

citations
Cited by 85 publications
(45 citation statements)
references
References 31 publications
0
45
0
Order By: Relevance
“…In this paper, we introduce a novel actuation scheme that combines PZT thin-film actuation with the principle of mechanical amplification, previously used for EM-actuated and ES-actuated scanners [2], [30], to achieve high-performance PZT-actuated resonant MEMS scanners. Fig.…”
mentioning
confidence: 99%
“…In this paper, we introduce a novel actuation scheme that combines PZT thin-film actuation with the principle of mechanical amplification, previously used for EM-actuated and ES-actuated scanners [2], [30], to achieve high-performance PZT-actuated resonant MEMS scanners. Fig.…”
mentioning
confidence: 99%
“…In this method, the scanner is actuated at the resonant frequency, where the displacement of the movable structure is enlarged. To further increase displacement in resonance, a cascaded mirror structure using mechanical coupling was reported [13][14][15] to enhance resonant work. In this method, the inner mirror is driven at a resonant frequency by applying force to a large outer frame.…”
Section: Large Mems Structuresmentioning
confidence: 99%
“…The role of the inner frame is to carry the MLA and serve as mechanical isolation between the MLA and the outer frame, where the actuation occurs [1]. A schematic drawing of the whole device is shown in Fig.…”
Section: Device Design and Fabricationmentioning
confidence: 99%
“…Laser scanning with microelectromechanical system (MEMS) mirrors is used in many display and imaging applications [1]- [6]. These systems typically utilize mirrors to steer the beam and thus require beam folding.…”
Section: Introductionmentioning
confidence: 99%