2012
DOI: 10.1039/c1ja10224a
|View full text |Cite
|
Sign up to set email alerts
|

Combination of a multimode sample introduction system with a pre-evaporation tube to improve multi-element analysis by ICP-OES

Abstract: A pre-evaporation tube (heated to 400 C) was inserted between a multi-mode sample introduction system (MSIS) and the plasma torch in inductively coupled plasma optical emission spectrometry (ICP-OES) to improve the simultaneous determination of hydride-forming and other elements. Multivariate optimisations were conducted to find operating conditions improving plasma robustness. Under these conditions and compared to conventional sample introduction with a pneumatic nebulizer and spray chamber, using MSIS with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
27
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 32 publications
(28 citation statements)
references
References 62 publications
1
27
0
Order By: Relevance
“…The enhancements in sensitivity are in agreement with those reported for the TISIS (8-15 fold), 28 PN-MSIS-PET (1-50 fold) 29 and USN-PET(IR) (10-25 fold) 2 systems, and are not due to a sole increase in R.F. power.…”
Section: Sensitivities Detection Limits and Precisionsupporting
confidence: 91%
See 2 more Smart Citations
“…The enhancements in sensitivity are in agreement with those reported for the TISIS (8-15 fold), 28 PN-MSIS-PET (1-50 fold) 29 and USN-PET(IR) (10-25 fold) 2 systems, and are not due to a sole increase in R.F. power.…”
Section: Sensitivities Detection Limits and Precisionsupporting
confidence: 91%
“…The sample introduction components did not need to be cleaned any more frequently than with PN at room temperature, unlike the previous PN-MSIS-PET system, which had to be cleaned aer only two days. 29 The washout time was about 3-4 s longer than that with the standard system at room temperature, despite the fact that the sample pumping rate was over 10 times smaller. Operating at 1.7 kW, i.e.…”
Section: Plasma Robustnessmentioning
confidence: 97%
See 1 more Smart Citation
“…The method was characterized, optimized, and applied to the determination of Co in a drug preparation, Pb in whole blood, and Sn in food samples without any sample pretreatment. Beauchemin et al 60,61 described the use of a preevaporation tube (PET) heated to 400 C, inserted between a multi-mode sample introduction system (MSIS) and the plasma torch for sample introduction to an ICP-AES. This modication improved the simultaneous determination of hydride forming and other elements compared with conventional sample introduction.…”
Section: Liquidsmentioning
confidence: 99%
“…A continuous-flow in-situ nebulizer/hydride generation system (MSIS) was coupled with ICP torch by means of a pre-evaporation tube heated to 400°C. This combination improved the analytical performance of multi-element analysis by ICP-OES as described by Asfaw and Beauchemin [4]. Also, the advantageous effect of spray chamber cooling on the analytical results obtained by ICP-OES and ICP-MS has been claimed for PN [5,6].…”
Section: Introductionmentioning