2019
DOI: 10.1016/j.ijpx.2019.100029
|View full text |Cite
|
Sign up to set email alerts
|

Combination of a rotating tube sample divider and dynamic image analysis for continuous on-line determination of granule size distribution

Abstract: Graphical abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…Unlike NIR, which can be disturbed by water, Raman spectroscopy can clearly display the scattering of the API, because water does not have a strong Raman spectrum [121]. The techniques for measuring the real-time change in particle size in the granulation process include imaging technology and FBRM [41,122]. The particle size, particle size distribution or particle growth rate present evidence to determine the endpoint of wet granulation; thus, their QAs can be used for the wet granulation scale-up step.…”
Section: Scale-up Studies On Wet Granulation Using a Pat-based Modeling Methodsmentioning
confidence: 99%
“…Unlike NIR, which can be disturbed by water, Raman spectroscopy can clearly display the scattering of the API, because water does not have a strong Raman spectrum [121]. The techniques for measuring the real-time change in particle size in the granulation process include imaging technology and FBRM [41,122]. The particle size, particle size distribution or particle growth rate present evidence to determine the endpoint of wet granulation; thus, their QAs can be used for the wet granulation scale-up step.…”
Section: Scale-up Studies On Wet Granulation Using a Pat-based Modeling Methodsmentioning
confidence: 99%
“…Unlike 2D devices, PartAn 3D measures the third dimension of the particle: thickness. Dynamic image analysis has found its application in granule research [15], in milling processes [16], [17], in particles analysis [18] or analysis of micro tablets [19]. The dried granules in the 0.4 -3 mm range characterized as product were analyzed to find their size and shape and the distribution curve width.…”
Section: Dynamic Image Analysismentioning
confidence: 99%
“…This results in difficulties to measure the full product flow as well as obtaining a representative sample to measure [20]. Therefore, limited research has been published on RCDG and in-line/on-line particle sizing [31][32][33].…”
Section: Introductionmentioning
confidence: 99%