Combination of air-source heat pumps with liquid desiccant dehumidification of air

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(21 citation statements)
references
References 17 publications
0
21
0
Order By: Relevance
“…Three subsystems in the above two FFASHP heating system contain the following components: evaporator, condenser, expansion valve, compressor, four-way valve, solution pump, sprinkler, solution tank or dehumidifier and regenerator. It should be noted that Figure 13 only gives simple schematic diagrams of the systems and their detailed structures can be referred to the relevant references [79,84,87]. (2) Main parameters For the FFASHP heating system based on method 1, the parameters of the test room and main components are listed in Table 4.…”
Section: Characteristics Of Different Frost-free Technologiesmentioning
confidence: 99%
See 3 more Smart Citations
“…Three subsystems in the above two FFASHP heating system contain the following components: evaporator, condenser, expansion valve, compressor, four-way valve, solution pump, sprinkler, solution tank or dehumidifier and regenerator. It should be noted that Figure 13 only gives simple schematic diagrams of the systems and their detailed structures can be referred to the relevant references [79,84,87]. (2) Main parameters For the FFASHP heating system based on method 1, the parameters of the test room and main components are listed in Table 4.…”
Section: Characteristics Of Different Frost-free Technologiesmentioning
confidence: 99%
“…For the FFASHP heating system based on method 2, the solution, the main components, the indoor and outdoor environment parameters in different studies are listed in Tables 6 and 7. Table 6 shows the parameters of numerical calculation of Zhang et al [84]. Table 7 summarizes the analysis calculation and design parameters when Su et al [73,87] and Yongcun et al [53] analyzed the performance of this FFASHP heating system.…”
Section: No Parameter Valuementioning
confidence: 99%
See 2 more Smart Citations
“…Simulation results showed that the proposed system consumed 51% less cooling energy compared to the conventional VAV (Variable Air Volume) system. A new type of frost-free air-source heat pump system with integrated liquid desiccant dehumidification was proposed [10], and the comparison results showed that COP of the frost-free air-source heat pump system was 30%e40% higher than that of heat pump heating integrated with an electric heater humidifying system. The effect of variable fresh air ratios on the performance of a liquid desiccant air conditioning was studied by Niu et al [11].…”
Section: Introductionmentioning
confidence: 99%