2013
DOI: 10.1007/s00216-013-6949-3
|View full text |Cite
|
Sign up to set email alerts
|

Combination of carbon isotope ratio with hydrogen isotope ratio determinations in sports drug testing

Abstract: Carbon isotope ratio (CIR) analysis has been routinely and successfully applied to doping control analysis for many years to uncover the misuse of endogenous steroids such as testosterone. Over the years, several challenges and limitations of this approach became apparent, e.g., the influence of inadequate chromatographic separation on CIR values or the emergence of steroid preparations comprising identical CIRs as endogenous steroids. While the latter has been addressed recently by the implementation of hydro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

4
54
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 38 publications
(58 citation statements)
references
References 37 publications
4
54
0
Order By: Relevance
“…[21][22][23] The results are depicted in Figure 7 and clearly demonstrate the potential of EPIA as a long term metabolite for T administration. [21][22][23] The results are depicted in Figure 7 and clearly demonstrate the potential of EPIA as a long term metabolite for T administration.…”
Section: Excretion Studiesmentioning
confidence: 79%
See 2 more Smart Citations
“…[21][22][23] The results are depicted in Figure 7 and clearly demonstrate the potential of EPIA as a long term metabolite for T administration. [21][22][23] The results are depicted in Figure 7 and clearly demonstrate the potential of EPIA as a long term metabolite for T administration.…”
Section: Excretion Studiesmentioning
confidence: 79%
“…[20][21][22][23][24] The HPLC clean-up was performed on an Agilent 1100 HPLC system (Waldbronn, Germany) equipped with a XBridge TM Shield RP18 5 mm (4.6 x 250 mm) column protected with a XBridge TM Shield RP18 5 mm (4.6 x 20 mm) guard column purchased from Waters (Eschborn, Germany). [20][21][22][23][24] The HPLC clean-up was performed on an Agilent 1100 HPLC system (Waldbronn, Germany) equipped with a XBridge TM Shield RP18 5 mm (4.6 x 250 mm) column protected with a XBridge TM Shield RP18 5 mm (4.6 x 20 mm) guard column purchased from Waters (Eschborn, Germany).…”
Section: Sample Preparation For Hir Determinationsmentioning
confidence: 99%
See 1 more Smart Citation
“…[14][15][16][17] In brief, samples were applied to a preconditioned solid-phase extraction (SPE) cartridge, washed with water, and eluted with methanol. [14][15][16][17] In brief, samples were applied to a preconditioned solid-phase extraction (SPE) cartridge, washed with water, and eluted with methanol.…”
Section: Elimination Studiesmentioning
confidence: 99%
“…A limitation of this methodology is the recent identification of a small minority of seized T product samples with nondepleted carbon isotope ratio [83] . The complementary development of hydrogen ion ratio MS further refines the ability to distinguish between endogenous and exogenous steroids in such cases [84,85] .…”
mentioning
confidence: 99%