2020
DOI: 10.1021/acs.iecr.0c01963
|View full text |Cite
|
Sign up to set email alerts
|

Combined Experimental and Theoretical Studies on the Prediction of the Isobaric Vapor–Liquid Association Phenomena for Binary and Ternary Mixtures of Water, Ethanoic Acid, and Propanoic Acid

Abstract: It is a considerable challenge for the phase behavior of chemical separation industry to correlate and predict the vapor–liquid equilibria (VLE) data of the binary and ternary systems containing associating components because it is not known how these forms exist in the experimental condition, such as homogeneous or heterogeneous dimers or trimers, even polymers, and so on. Herein, VLE data for the associating ternary system, water + ethanoic acid + propanoic acid, and the three-constituent binary systems have… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
1
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 80 publications
1
1
0
Order By: Relevance
“…We have tested the effect of basis set superposition error (BSSE) for the binding energy of dimer, trimer, pentamer and octamer and presented in the Table S2 in SI. Our results are in consistent with previous literatures [37,39,40]. The contribution of the BSSE to the total binding energy of water cluster is only around 1 kJ/mol per water-water interaction.…”
Section: Methodssupporting
confidence: 93%
“…We have tested the effect of basis set superposition error (BSSE) for the binding energy of dimer, trimer, pentamer and octamer and presented in the Table S2 in SI. Our results are in consistent with previous literatures [37,39,40]. The contribution of the BSSE to the total binding energy of water cluster is only around 1 kJ/mol per water-water interaction.…”
Section: Methodssupporting
confidence: 93%
“…The VLE data were measured by using a VLE still ( i -Fischer Labodest VLE 602-D, Germany). The reliable validation of experimental measurements from the device is available in our previous references. , Before each experiment, the ILs were pretreated by including rotary evaporation and drying in a vacuum oven for 6 h. The samples were weighed by using a Sartorius electronic balance (model ER-182A) with an accuracy of 0.0001 g. The mass of the added components was predetermined and measured by a differential weighing method. Then, the demanded components were introduced into the still using a syringe.…”
Section: Methodsmentioning
confidence: 99%