2020
DOI: 10.1007/s40313-020-00634-4
|View full text |Cite
|
Sign up to set email alerts
|

Combined SHE-LLCL Design for a Real Case Photovoltaic Power Station

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Filters. Regardless LCL or LLCL [10], both filters combined with SHM respect successfully grid code requirements as shown in Figure 16. is appreciable result can be attributed e spectrum obtained with LLCL filters better than the LCL filter as almost harmonics amplitude is lower than the LCL filter.…”
Section: Frequency Domain Comparison Between Lcl and Llclmentioning
confidence: 85%
See 1 more Smart Citation
“…Filters. Regardless LCL or LLCL [10], both filters combined with SHM respect successfully grid code requirements as shown in Figure 16. is appreciable result can be attributed e spectrum obtained with LLCL filters better than the LCL filter as almost harmonics amplitude is lower than the LCL filter.…”
Section: Frequency Domain Comparison Between Lcl and Llclmentioning
confidence: 85%
“…e same electrical scheme using the LCL filter is considered, but the leakage inductor related to the cable length has been added as shown in Figure 6. at makes the LLCL filter flexible as its behavior depends on the cable length which is optimized in [10]. e leakage inductor of a tertiary cabling is named L 3Y1 .…”
Section: Equivalent Electrical Diagram Modelingmentioning
confidence: 99%
“…In autumn, the temperature and irradiance decreased [16] , and PR did not change much. This was due to the combined effect of the increase of component efficiency caused by the decrease of temperature and the decrease of irradiance [19] , while the change of PRstc was larger.…”
Section: Annual and Monthly Prstc Analysis Of Power Stationmentioning
confidence: 91%
“…Tis system is already presented in [11]. Te flter inductor is integrated with the transformer to lower the overall volume and weight of the system, resulting in cost savings.…”
Section: Problem Description Of a Real Case Of One Mw Pv Substationmentioning
confidence: 99%
“…Te flter inductor is integrated with the transformer to lower the overall volume and weight of the system, resulting in cost savings. Te tertiary inductor is caused by the leakage inductance of the cables used to link the capacitor's bank to the tertiary: it is also proved in [11] that this parameter has a signifcant infuence on harmonic rejections.…”
Section: Problem Description Of a Real Case Of One Mw Pv Substationmentioning
confidence: 99%