2012
DOI: 10.1055/s-0031-1271117
|View full text |Cite
|
Sign up to set email alerts
|

Combined Staging at One Stop Using MR Mammography: Evaluation of an Extended Protocol to Screen for Distant Metastasis in Primary Breast Cancer – Initial Results and Diagnostic Accuracy in a Prospective Study

Abstract: Applying the extended MRI protocol, accurate screening for distant metastasis was possible in combination with a dedicated breast examination.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 6 publications
1
5
0
Order By: Relevance
“…The total acquisition time of this “half-body”-sequence was 51 s ( Table 1 ). This protocol has been previously described in [18] , [19] . MRI examinations were evaluated by two experienced radiologists (one with an experience of >15.000 cases, the other with an experience of >1.000 cases in MRI).…”
Section: Methodsmentioning
confidence: 99%
“…The total acquisition time of this “half-body”-sequence was 51 s ( Table 1 ). This protocol has been previously described in [18] , [19] . MRI examinations were evaluated by two experienced radiologists (one with an experience of >15.000 cases, the other with an experience of >1.000 cases in MRI).…”
Section: Methodsmentioning
confidence: 99%
“…Kirchner et al [ 98 ] proposed a complete whole body positron emission tomography/MRI staging. On the other hand, abbreviated protocols enabling screening for breast cancer metastasis are available as well [ 99 , 100 ]. Requiring only 90 s of additional examination time, such protocols can be combined with a standard breast MRI within one single examination.…”
Section: P2-bmri: Semantic Criteriamentioning
confidence: 99%
“…Requiring only 90 s of additional examination time, such protocols can be combined with a standard breast MRI within one single examination. Initial clinical data demonstrated promising results regarding both lymph node staging (positive predictive value of 100%, negative predictive value of 94.3%) and distant metastases screening (sensitivity 100%, specificity 98.3%) [ 99 , 100 ].…”
Section: P2-bmri: Semantic Criteriamentioning
confidence: 99%
“…2,3 However, PET, specifically positron emission mammography, is also used in focused breast examinations 4 and whole-body MR imaging has also been used in imaging metastatic spread. 5,6 PET and MR images of the breast have been fused 710 to investigate potential benefits of combining these modalities. Now, PET/MR imaging hybrid scanners, depending on the model, simultaneously or sequentially acquire and coregister PET and MR imaging data.…”
Section: Introductionmentioning
confidence: 99%