2019
DOI: 10.1007/s10554-019-01727-1
|View full text |Cite
|
Sign up to set email alerts
|

Combined use of electro-anatomic mapping system and intracardiac echocardiography to achieve zero-fluoroscopy catheter ablation for treatment of paroxysmal atrial fibrillation: a single centre experience

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 30 publications
0
12
0
Order By: Relevance
“…The application of ICE during AF ablation has increased over the years and is associated with lower procedural complications and in‐hospital mortality 14 . Several studies to date have evaluated the feasibility and outcome of zero‐fluoroscopy catheter ablation of AF with combined use of a three‐dimensional electro‐anatomic mapping system and ICE 15,16 . Our study applied the currently available technologies: ICE, CartoSound electroanatomical mapping system, and contact force sensing catheter, along with high power ablation strategy 17 and AI guidance 18 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The application of ICE during AF ablation has increased over the years and is associated with lower procedural complications and in‐hospital mortality 14 . Several studies to date have evaluated the feasibility and outcome of zero‐fluoroscopy catheter ablation of AF with combined use of a three‐dimensional electro‐anatomic mapping system and ICE 15,16 . Our study applied the currently available technologies: ICE, CartoSound electroanatomical mapping system, and contact force sensing catheter, along with high power ablation strategy 17 and AI guidance 18 .…”
Section: Discussionmentioning
confidence: 99%
“…14 Several studies to date have evaluated the feasibility and outcome of zero-fluoroscopy catheter ablation of AF with combined use of a three-dimensional electro-anatomic mapping system and ICE. 15,16 Our study applied the currently available technologies: ICE, CartoSound electroanatomical mapping system, and contact force sensing catheter, along with high power ablation strategy 17 and AI guidance. 18 This study demonstrated that AI-guided high-power fluoroless ablation for AF under ICE guidance is fully effective and safe.…”
Section: Efficacy and Safety Of Ai-guided High-power Fluoroless Af Ab...mentioning
confidence: 99%
“…Fluoroless PVI for paroxysmal and persistent AF or more complex arrhythmias such as LA flutter utilizing ICE imaging and EAM has been reported elsewhere 10,11,12,20 . In contrast to these studies, we used ICE/EAM automatic integration system as the primary tool for reconstructing detailed virtual anatomical 3D map of all relevant LA structures.…”
Section: Discussionmentioning
confidence: 99%
“…14 Very few studies to date have evaluated the feasibility and outcome of zero-fluoroscopy catheter ablation of AF with combined use of a three-dimensional electroanatomic mapping system and ICE. 15,16 Our study applied the currently available technologies: ICE, CAR-TOSOUND electroanatomical mapping system and contact force sensing catheter, along with high power ablation strategy 17 and AI guidance 18 . This study demonstrated that AI-guided high-power fluoroless ablation for AF under ICE guidance is fully effective and safe.…”
Section: Discussionmentioning
confidence: 99%