2020
DOI: 10.1161/jaha.119.014683
|View full text |Cite
|
Sign up to set email alerts
|

Combining Optimized Image Processing With Dual Axis Rotational Angiography: Toward Low‐Dose Invasive Coronary Angiography

Abstract: Background Dual axis rotational coronary angiography ( DARCA ) reduces radiation exposure during coronary angiography on older x‐ray systems. The purpose of the current study is to quantify patient and staff radiation exposure using DARCA on a modality already equipped with dose‐reducing technology. Additionally, we assessed applicability of 1 dose area product to effective dose conversion factor for both DARCA … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…For instance, in the PROMISE trial, nuclear perfusion imaging had a median effective radiation dose of 12.6 mSv [17]. On the other hand, conventional diagnostic invasive coronary angiography requires approximately 4.75 mSv, with possible dose reduction down to 1.8 mSv, using novel methods such as dual-axis rotational angiography [19].…”
Section: Discussionmentioning
confidence: 99%
“…For instance, in the PROMISE trial, nuclear perfusion imaging had a median effective radiation dose of 12.6 mSv [17]. On the other hand, conventional diagnostic invasive coronary angiography requires approximately 4.75 mSv, with possible dose reduction down to 1.8 mSv, using novel methods such as dual-axis rotational angiography [19].…”
Section: Discussionmentioning
confidence: 99%
“…The occupational eye dose was measured via the DoseAware dosimetry system (Philips Healthcare, Best, Netherlands). The DoseAware system consists of badges that are solid-state active personal dosimeters which log occupational radiation dose per second cumulatively [ 21 ]. DoseAware badges have been demonstrated to detect satisfactorily within varying pulse widths, tubevoltages and dose rates [ 22 , 23 ] and have a reported uncertainty of 5% [ 24 ].…”
Section: Methodsmentioning
confidence: 99%
“…DoseAware badges consist of a solid-state active personal dosimeter which log the dose per second cumulatively 36 . Occupational dosimeter measurements will have a degree of variability due to the effect of photon incident angles, energy range and pulsed-field characteristics 37 .…”
Section: Methodsmentioning
confidence: 99%