2014
DOI: 10.1583/13-4514c.1
|View full text |Cite
|
Sign up to set email alerts
|

Commentary: Multilayer Stent for the Treatment of Complex Aortic Pathologies: A Long or Short Road Ahead?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…For avoidance of endoleak and other complications, previous investigators also stress the importance of (1) deployment within nonaneurysmal native aortic landing zones of at least 20 mm, (2) pretreatment of concomitant stenosis in the collaterals to be covered by the device, (3) adequate device oversizing, and (4) adherence to dual antiplatelet therapy. 12,29,31…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…For avoidance of endoleak and other complications, previous investigators also stress the importance of (1) deployment within nonaneurysmal native aortic landing zones of at least 20 mm, (2) pretreatment of concomitant stenosis in the collaterals to be covered by the device, (3) adequate device oversizing, and (4) adherence to dual antiplatelet therapy. 12,29,31…”
Section: Discussionmentioning
confidence: 99%
“…Published studies consistently stress the crucial importance of strict compliance with the MFM IFU, including the guidelines for patient selection. 12,15,[29][30][31]38 Established contradictions to use of the MFM include ruptured aneurysm, connective tissue disorders, mycotic aneurysms, and concomitant or previously implanted stent-grafts. 30 Vaislic et al 29 articulate some important technical points related to the reproducibility of positive outcomes with the MFM.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Rather than "excluding" the aneurysm, the MFMS is freely porous but blood-flow through the stent is laminated reducing turbulence in the aneurysm sac leading to sac thrombosis. As the stent is uncovered and highly porous, it can be deployed across the origins of major aortic branches maintaining organ perfusion 1,2 (Fig. 1).…”
Section: Introductionmentioning
confidence: 99%
“…Recent studies suggest acceptable early results in aortic aneurysms, 3,4 aortic dissections, 3,4 and peripheral and visceral aneurysms, 5 although the consequences of using this device outside of the instructions for use (IFU) have been well documented. 2,6 This study reports experience with the first-generation MFMS device in a UK pilot study recruiting patients with thoracoabdominal (TAAA) and peri-renal (PAA) aortic aneurysms.…”
Section: Introductionmentioning
confidence: 99%