Commissioning and quality assurance of HalcyonTM 2.0 linear accelerator

Abstract: This article is available in open access under creative common attribution-Non-commercial-No Derivatives 4.0 International (cc BY-Nc-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 26 publications
0
3
0
Order By: Relevance
“…The dosimeters were irradiated on the CAX in a MP3-T water tank phantom (PTW, Freiburg, Germany). Since optical SSD indicators or a light field are not provided by the closed gantry system of the Halcyon, [17][18][19][20] MV imaging was applied to verify the vertical setup of the water tank. Depth dose curves and lateral dose profiles were measured with the Tandem electrometer T10011, the TBA control unit T41013 and the Mephysto mc 2 software package (PTW, Freiburg, Germany).…”
Section: General Methodsmentioning
confidence: 99%
“…The dosimeters were irradiated on the CAX in a MP3-T water tank phantom (PTW, Freiburg, Germany). Since optical SSD indicators or a light field are not provided by the closed gantry system of the Halcyon, [17][18][19][20] MV imaging was applied to verify the vertical setup of the water tank. Depth dose curves and lateral dose profiles were measured with the Tandem electrometer T10011, the TBA control unit T41013 and the Mephysto mc 2 software package (PTW, Freiburg, Germany).…”
Section: General Methodsmentioning
confidence: 99%
“…The Varian Ethos (Varian Medical Systems, Palo Alto, CA), introduced in 2019, pairs the closed bore Halcyon linac with dedicated treatment planning and record and verify systems. The Halcyon linac provides a 6 MV flattening filter free (FFF) beam and kV iterative cone-beam CT (iCBCT) imaging, with a minimum CBCT acquisition time of 17 s (Netherton et al 2019, Pathak et al 2021. A streamlined adaptive workflow is enabled in part through artificial intelligence (AI)-based auto-contouring of relevant organs at risk (OARs) and rapid plan re-optimization capabilities.…”
Section: Varian Ethosmentioning
confidence: 99%
“…Halcyon 2.0 imaging no longer requires MV-X rays but adds a dedicated kV imaging system with greatly improved soft tissue resolution. [2] It has a gantry speed of up to 4 rotations a minute. Since there is no field light, optical distance indicator or source-skin distance (SSD) measuring device, only the laser on the machine shell is used for patient positioning.…”
Section: Introductionmentioning