Commissioning of the Pair Spectrometer of the GlueX experiment

Abstract: Abstract. The main goal of the pair spectrometer of the GlueX experiment at Jefferson Lab is to determine the photon beam flux and to measure beam polarization. We present the design of the pair spectrometer and the performance results during fist commissioning runs of the GlueX experiment. IntroductionThe GlueX is the new experiment in the experimental Hall D at Thomas Jefferson Accelerator Facility, whose main goal is to search for mesons with exotic quantum numbers using a beam of linearly polarized photons… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…On-beam tests were performed with two setups of increasing complexity. In the first experiment, a 3 × 3 PbWO 4 matrix was placed downstream of a secondary electron/positron beam generated by the primary photon beam in Hall-D. Leptons were identified and their energy measured by a Pair Spectrometer tagger (PS) [7,8]. This enabled a precise determination of the energy and a quantitative comparison between SRO and triggered clustering algorithms.…”
Section: Detector Setupmentioning
confidence: 99%
“…On-beam tests were performed with two setups of increasing complexity. In the first experiment, a 3 × 3 PbWO 4 matrix was placed downstream of a secondary electron/positron beam generated by the primary photon beam in Hall-D. Leptons were identified and their energy measured by a Pair Spectrometer tagger (PS) [7,8]. This enabled a precise determination of the energy and a quantitative comparison between SRO and triggered clustering algorithms.…”
Section: Detector Setupmentioning
confidence: 99%
“…The typical rate of PS double-arm coincidences is a few kHz. Details about the performance of the spectrometer are given in [27,28].…”
Section: Pair Spectrometermentioning
confidence: 99%
“…The solenoid employs a cryostatically stable design with cryostats designed to be opened and serviced with hand tools. The magnet was refurbished and modified 27 for the GlueX experiment [35,36].…”
Section: Overviewmentioning
confidence: 99%
“…The power supply 27 provides up to 10 V DC for establishing the operating current while ramping. The supply also includes a protection circuit, which can be engaged by a quench detector as well as by other signals.…”
Section: Conductor and Coilsmentioning
confidence: 99%