2016
DOI: 10.1109/tasc.2016.2525935
|View full text |Cite
|
Sign up to set email alerts
|

Commissioning Test Results of Variable-Temperature Helium Refrigerator/Liquefier for NIFS Superconducting Magnet Test Facility

Abstract: The superconducting magnet test facility in the National Institute for Fusion Science has been upgraded for excitation tests at a wide temperature range and a higher magnetic field of 13 T. As part of the upgrade, the helium refrigerator/liquefier operated for 24 years was replaced with a variable temperature helium refrigerator/liquefier. The required liquefaction rate is 250 L/h and the required refrigeration capacity is 600 W at 4.5 K as the previous one. Besides, it has a new feature that can supply helium… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…Energization tests of the sample were conducted using the 13 T test facility of the National Institute for Fusion Science (NIFS) [11,12]. The sample was installed into a vacuum vessel located in a bore of an external field coil.…”
Section: Methodsmentioning
confidence: 99%
“…Energization tests of the sample were conducted using the 13 T test facility of the National Institute for Fusion Science (NIFS) [11,12]. The sample was installed into a vacuum vessel located in a bore of an external field coil.…”
Section: Methodsmentioning
confidence: 99%
“…A large bore (700 mm in diameter) and high field (13 T) magnet test facility 15 , a 9-T split coil, 75-kA DC power supply, and temperature-variable (4-50 K) refrigerator 16 have been installed for testing various superconducting conductor and coil samples. These facilities have been used for testing the performance of short HTS conductor samples 17 , the ITER-TF joint samples 18 , and the JT-60SA CS model and module coils 19 .…”
Section: Ii-b Major Fusion Engineering Facilities In Nifs and Their C...mentioning
confidence: 99%
“…High temperature superconducting magnet 13 T, φ700 mm Solenoid Coil 15 , 9T Split Coil, Temperature Variable Refrigerator 16 Short HTS sample tests 17 ITER-TF Joint Sample tests 18 JT-60SA Central Solenoid tests 19 Blanket…”
Section: Research Subjects Major Emphases Key Facilities In Nifs Exam...mentioning
confidence: 99%
“…[6,7,10,11]. The helium cryogenics system of the test facility was upgraded in the 2014 Japanese Fiscal Year [12]. Fig.…”
Section: Test Facilitymentioning
confidence: 99%